User manual

Configuration Commands RLXIC-SG Intelligent Cellular
User Manual RadioLinx Intelligent Cellular Serial Modem for Global GPRS/GSM
ProSoft Technology, Inc. Page 101 of 136
May 29, 2009
\Qn
Set or query the serial port flow control setting.
n=0 : No flow control is being used.
n=1 : RTS/CTS hardware flow control is being used.
n=4 : Transparent software flow control. Uses escaped XON and XOFF for
flow control. XON and XOFF characters in data stream are escaped with the
@ character (0x40). @ in data is sent as @@.
+FCLASS=n
This command sets the RLXIC-SGinto a particular fax-mode operation, which
causes the internal hardware to process information presented in the Dial
command in a manner suitable for that type of information. Cannot be configured
in AceManager.
n=0 : Fax/data call.
n=8 : Normal interconnect.
+WVCLASS? queries the current setting.
+IPR=n
I/O Port Rate: Sets the data rate for the serial port (DTE-DCE). C3x11 or C3x11E
only. Default is 115200. Cannot be configured in AceManager.
+WVLASS=n
This command sets the RLXIC-SG into a particular voice-mode operation, which
causes the internal hardware to process information presented in the Dial
command in a manner suitable for that type of information. Cannot be configured
in AceManager.
n=0 : Normal interconnect (using line 1).
n=9 : Fax/data call.
$QCVAD=n
Mode for answering data or fax with the A (answer) or via auto answer (S0=1).
C3x10 or C3x10E only. Cannot be configured in AceManager.
*CTSE=n
Clear To Send Enable: This feature asserts CTS when there is a network
connection.
n=0 : Disabled (Default).
n=1 : Enable assertion of CTS when there is network coverage.
RS232 voltage levels:
Positive = Network coverage.
Negative = No coverage.