User manual

RLXIC-EV Intelligent Cellular Configuring your RLXIC-EV
RadioLinx® Intelligent Cellular Ethernet Gateway for Verizon User Manual
Page 82 of 104 ProSoft Technology, Inc.
March 10, 2010
5.11 Report Configuration
5.11.1 Reports Server
Reports using the Events Protocol are sent to the Reports Server.
Event Reporting allows the RLXIC-EV to send reports to a remote server. The
Reports Server would be running an application to parse the messages and send
responses to the RLXIC-EV devices.
5.11.2 Server 1
Field AT Command Description
Report Server IP *PPIP
IP address where Event Reports are sent (RAP Server IP).
Also see *PPPORT.
d.d.d.d=IP address
Example:
AT*PPIP=192.100.100.100
Server Port *PPPORT Port where Event Reports are sent.
n=1-65535
Minimum Report
Time (secs)
*PPMINTIME Report Time Interval.
n=seconds (1 - 65535)
Note: Your cellular carrier may impose a minimum transmit
time.
Caution: A report time of less than 30 seconds can
possibly keep an RF link up continuously. This could
eventually cause the device to overheat and shutdown. An
RF resource may continue be tied up to transfer small
amounts of data. Generally the RF channel will be
released and go dormant in 10-20 seconds of no data sent
or received.