User manual
Table Of Contents
- Start Here
- Configuring the Processor with Concept
- Configuring the Processor with ProWORX
- Configuring the Processor with UnityPro XL
- To build (compile) the project:
- To verify address and driver settings in UnityPro XL:
- Setting Up the ProTalk Module
- Configuring the Module
- Diagnostics and Troubleshooting
- Reading Status Data From the Module
- The Configuration/Debug Menu
- Required Hardware
- Required Software
- Using the Configuration/Debug Port
- Main Menu
- Opening the Data Analyzer Menu
- Viewing Block Transfer Statistics
- Viewing Module Configuration
- Opening the Database Menu
- Opening the Backplane Menu
- Transferring the Configuration File from PC to PTQ module
- Transferring the Configuration File from PTQ module to PC
- Viewing Version Information
- Warm Booting the Module
- Viewing Port Communication Status
- Viewing Port Configuration
- Exiting the Program
- Database View Menu
- Viewing Register Pages
- Displaying the Current Page of Registers Again
- Moving Back Through 5 Pages of Registers
- Viewing the Previous 100 Registers of Data
- Skipping 500 Registers of Data
- Viewing the Next 100 Registers of Data
- Viewing Data in Decimal Format
- Viewing Data in Hexadecimal Format
- Viewing Data in Floating Point Format
- Viewing Data in ASCII (Text) Format
- Returning to the Main Menu
- Backplane Menu
- Data Analyzer
- Data Analyzer Tips
- LED Status Indicators
- Reading Status Data From the Module
- Reference
- Index

Reference PTQ-LNG ♦ Quantum / Unity Platform
Landis & Gyr Telegyr Interface Module
ProSoft Technology, Inc. Page 95 of 103
May 29, 2007
8.7.5 Does the module work in a remote rack?
The module is designed to be located in the chassis with the PLC and will not
operate in a remote chassis. If your application requires remote placement of the
communication device you should investigate the other members of the ProLinx
family such as the 4202-MNET-DFCM. (if you require DF1 connectivity for
instance although many others are available) This module for example would
allow you to communicate with DF1 devices and allow you to map the contents of
its memory using Modbus TCP/IP.
8.7.6 Can I use the module in a hot backup system?
Support for Hot Backup is not currently implemented in the module. We are
currently investigating the addition of this functionality but until this development
can be finalized, it may be possible to use one of the 4000 series of ProSoft
communication products. Please call our technical support technicians when
considering this application.