User manual
Table Of Contents
- Start Here
- Configuring the Processor with Concept
- Configuring the Processor with ProWORX
- Configuring the Processor with UnityPro XL
- To build (compile) the project:
- To verify address and driver settings in UnityPro XL:
- Setting Up the ProTalk Module
- Configuring the Module
- Diagnostics and Troubleshooting
- Reading Status Data From the Module
- The Configuration/Debug Menu
- Required Hardware
- Required Software
- Using the Configuration/Debug Port
- Main Menu
- Opening the Data Analyzer Menu
- Viewing Block Transfer Statistics
- Viewing Module Configuration
- Opening the Database Menu
- Opening the Backplane Menu
- Transferring the Configuration File from PC to PTQ module
- Transferring the Configuration File from PTQ module to PC
- Viewing Version Information
- Warm Booting the Module
- Viewing Port Communication Status
- Viewing Port Configuration
- Exiting the Program
- Database View Menu
- Viewing Register Pages
- Displaying the Current Page of Registers Again
- Moving Back Through 5 Pages of Registers
- Viewing the Previous 100 Registers of Data
- Skipping 500 Registers of Data
- Viewing the Next 100 Registers of Data
- Viewing Data in Decimal Format
- Viewing Data in Hexadecimal Format
- Viewing Data in Floating Point Format
- Viewing Data in ASCII (Text) Format
- Returning to the Main Menu
- Backplane Menu
- Data Analyzer
- Data Analyzer Tips
- LED Status Indicators
- Reading Status Data From the Module
- Reference
- Index

Reference PTQ-LNG ♦ Quantum / Unity Platform
Landis & Gyr Telegyr Interface Module
ProSoft Technology, Inc. Page 85 of 103
May 29, 2007
PTQ-LNG Database Map
The following table shows the layout of the database.
Start Address End Address Data Quantum Address
0 299 Analog Inputs 401064 to 401363
300 349 Digital Inputs 401364 to 401413
350 399 Accumulators 401414 to 401463
400 449 Indication Points 401464 to 401513
600 649 Analog Outputs 300164 to 300213
650 699 Digital Outputs 300214 to 300263
700 749 Accumulator Presets 300264 to 300313
750 Pulse Raise 10ms Control 300314
751 759 Pulse Raise 10ms 300315 to 300323
760 Pulse Lower 10ms Control 300324
761 769 Pulse Lower 10ms 300325 to 300333
770 Pulse Raise 100ms Control 300334
771 779 Pulse Raise 100ms 300335 to 300343
780 Pulse Lower 100ms Control 300344
781 789 Pulse Lower 100ms 300345 to 300353
790 Pulse Raise 1s Control 300354
791 799 Pulse Raise 1s 300355 to 300363
800 Pulse Lower 1s Control 300364
801 809 Pulse Lower 1s 300365 to 300373
810 Pulse Raise 10s Control 300374
811 819 Pulse Raise 10s 300375 to 300383
820 Pulse Lower 10s Control 300384
821 829 Pulse Lower 10s 300385 to 300393
850 SBO Command 300414
851 SBO Bit 300415
852 SBO Operate 300416
853 SBO Duration 300417
860 PTO Active 300424
861 PTO Point 300425
862 PTO Command 300426
863 PTO Count 300427
864 PTO On Duration 300428
865 PTO Off Duration 300429
2000 RTU Config I/O Chassis Internal Only
2001 Chassis Number Internal Only
2002 2017 Card Code Internal Only
2018 Chassis Number 1 Internal Only
2019 2034 Card Code Internal Only