PTQ-PDPMV1 Quantum Platform Configuring the Module
PROFIBUS DP Master Network Interface Module for Quantum User Manual
ProSoft Technology, Inc. Page 39 of 306
August 12, 2014
6 Double click the SLAVE icon to view the Slave properties.
In particular, note the following settings:
o Automatic PROFIBUS Address Assignment:
ProSoft Configuration Builder automatically assigns a PROFIBUS address
to each new slave. The address assignment begins at address 3, and is
incremented by 1 for each new slave added to the network. You can
change the address in the COMMON tab of the Slave Properties dialog
box.
o Automatic Input/Output Address Assignment:
For each new slave added to the PROFIBUS network, ProSoft
Configuration Builder automatically converts the input/output byte
addresses to word input/output addresses for the State RAM in the
processor.
7 Repeat steps 2 through 6 for all slaves you intend to place on the network.
8 When you are finished adding slaves, open the PROJECT menu and choose
EXIT to return to the Master Setup dialog box.