User manual

Contents ILX800-SMSG Micro800 Platform
User Manual SMS Text Plug-in Module for GSM Networks
Page 18 of 39 ProSoft Technology, Inc.
September 14, 2012
Note: The slot closest to the power supply side of the controller is Slot 1. The next one is Slot 2, etc.
2.4 Entering a Test Phone Number
Set up a test phone number in the sample program. Once the program has been
downloaded, the module will send out a greeting text message on boot-up to this phone
number.
1 Double-click the LOCAL VARIABLES icon for the PSFT_ILX800_SMSG program in the
Project Organizer pane.
2 Click the header of the NAME column to sort the variables alphabetically.
3 Find the variable CONFIG_receiverList in the Name column. Click the [+] sign next to
CONFIG_receiverList to expand it.
4 Enter an area code and phone number in the Initial Value column. Do not enter any
spaces, parentheses or hyphens.
For more information about entering phone numbers in the Receiver List, see Receiver List.
2.5 Connecting the Controller to Your PC
You will need a Type A/B USB cable to connect the Micro830 controller to your PC.
1 Connect the USB cable's Type A plug to a USB jack on your PC.
2 Connect the USB cable's Type B plug to the USB jack on the controller.
3 If the driver for the USB connection to the controller is not already installed on your PC,
Windows will launch the Found New Hardware Wizard. Follow the prompts to install the
driver.
Note: RSLinx will automatically configure and start the AB_VBP-x driver for the USB connection.
2.6 Downloading the Sample Program
Note: The mode switch on the front of the controller must be in the REM or PRG position.
1 Click the icon to save the project.