User manual
1560-PDP
PROFIBUS – SCANport Adapter
17
Vendor_Name = "ProSoft Technology Inc"
Model_Name = "1560-PDP SCANport Adapter"
Revision = "Rev 1.0 - 1";
Ident_Number = 0x087C ; Need official ID from PTO
Protocol_Ident = 0 ; 0 = Profibus DP
Station_Type = 0 ; 0 = DP Slave
FMS_supp = 0 ; No FMS support
Hardware_Release = "01" ; Not a function of Hardware Release
Software_Release = "1" ; Batch Number
;
; Supported Baud Rates
9.6_supp = 1
19.2_supp = 1
93.75_supp = 1
187.5_supp = 1
500_supp = 1
1.5M_supp = 1
3M_supp = 1
6M_supp = 1
12M_supp = 1
;
; Maximum Responder time for supported baud rates
MaxTsdr_9.6 = 60
MaxTsdr_19.2 = 60
MaxTsdr_93.75 = 60
MaxTsdr_187.5 = 60
MaxTsdr_500 = 100
MaxTsdr_1.5M = 150
MaxTsdr_3M = 250
MaxTsdr_6M = 450
MaxTsdr_12M = 800
;
; Supported hardware features
Redundancy = 0 ; Not supported
Repeater_Ctrl_Sig = 2 ; TTL
24V_Pins = 0 ; Not Connected
Implementation_Type= "SPC3"
;
;
;
; Supported DP Features
Freeze_Mode_supp = 1 ; supported
Sync_Mode_supp = 1 ; supported
Auto_Baud_supp = 1 ; supported
Set_Slave_Add_supp= 0 ; DIP Switch config address
;
;
;
; Maximum Polling Frequency
Min_Slave_Intervall = 1 ; 100 us
;
; Device Type
Slave_Family = 1 ; 1 = Drives
;
; Maximum supported sizes
Modular_Station = 1 ; Compact station - Predefined I/O
Max_Module = 5