Specifications

ProLinx Communication Gateways, Inc. 71
HART Master Protocol Drive Manual
August 17, 2004
COMMAND 58: Write Unit Tag Descriptor Date
Description:
This command writes an ASCII Tag which identifies the device, an ASCII
descriptor of the device and the last Date it has been configured.
Write Parameters:
WORD HIGH BYTE LOW BYTE
0 Packed ASCII TAG Byte 0 Packed ASCII TAG Byte 1
1 Packed ASCII TAG Byte 2 Packed ASCII TAG Byte 3
2 Packed ASCII TAG Byte 4 Packed ASCII TAG Byte 5
3 Packed ASCII Descriptor Byte 0 Packed ASCII Descriptor Byte 1
.
.
.
.
.
.
8 Packed ASCII Descriptor Byte 10 Packed ASCII Descriptor Byte 11
9 Date Date
10 Date 0
Floating Point Data Returned:
NONE
Integer Data Returned:
WORD HIGH BYTE LOW BYTE
0 STATUS WORD
1 TAG ASCII Character 0 TAG ASCII Character 1
2 TAG ASCII Character 2 TAG ASCII Character 3
3 TAG ASCII Character 4 TAG ASCII Character 5
4 TAG ASCII Character 6 TAG ASCII Character 7
5 Descriptor ASCII Character 0 Message ASCII Character 1
.
.
.
.
.
.
12 Descriptor ASCII Character 14 Message ASCII Character 15
13 Date Date
14 Date 0