Specifications
ProLinx Communication Gateways, Inc. 35
HART Master Protocol Drive Manual
August 17, 2004
COMMAND 02: Read Current And Percent Of Range
Description:
This command gets the current of the loop that is forced by the HART device and
the Percent of Range of the Current.
Write Parameters:
NONE
Floating Point Data Returned:
WORD HIGH BYTE LOW BYTE
0
1
Current (mA)
2
3
Percent of Range
Integer Data Returned:
WORD HIGH BYTE LOW BYTE
0 STATUS WORD