User manual

Diagnostics and Troubleshooting ProLinx DNPS ProLinx Gateway
User Manual DNP 3.0 Slave
ProSoft Technology, Inc. Page 33 of 86
December 1, 2009
This action opens the DIAGNOSTICS dialog box.
3 Press [?]
to open the Main Menu.
Important: The illustrations of configuration/debug menus in this section are intended as a general
guide, and may not exactly match the configuration/debug menus in your own module.
If there is no response from the module, follow these steps:
1 Click to configure the connection. On the Connection Setup dialog box, select
a valid com port or other connection type supported by the gateway.
2 Verify that the null modem cable is connected properly between your
computer’s serial port and the module. A regular serial cable will not work.
3 On computers with more than one serial port, verify that your communication
program is connected to the same port that is connected to the module.