User manual

ProLinx DNPS ProLinx Gateway Start Here
DNP 3.0 Slave User Manual
Page 16 of 86 ProSoft Technology, Inc.
December 1, 2009
Float Outputs
0 to 250 points
Number of floating point output points to configure in the DNP slave device. Each
point will occupy a two-word area in the module's memory.
Double Outputs
0 to 125 points
Number of double floating point output points to configure in the DNP slave
device. Each point will occupy a four-word area in the module's memory.
Baud Rate
This is the baud rate to be used on the port. Enter the baud rate as a value. For
example, to select 19K baud, enter 19200.
Baud Rate Parameter Value
110 110
150 150
300 300
600 600
1200 12 or 1200
2400 24 or 2400
4800 48 or 4800
9600 96 or 9600
19,200 19, 192 or 19200
28,800 28, 288 or 28800
57,600 57 or 576
115,200 115 or 1152
Parity
None, Odd, Even
Parity is a simple error checking algorithm used in serial communication. This
parameter specifies the type of parity checking to use.
All devices communicating through this port must use the same parity setting.
Data Bits
7
or 8
This parameter sets the number of data bits for each word used by the protocol.
All devices communicating through this port must use the same number of data
bits.