User manual
Ladder Logic ILX34-AENWG ♦ Point I/O Platform
User Manual Wireless POINT I/O Adapter
Page164of209 ProSoftTechnology,Inc.
September19,2011
1734-IJ, 1734-IK
1734 POINT I/O Catalog Number RSLogix5000 Module Description
1734-IJ 1 Channel 5V dc Encoder / Counter
1734-IK 1 Channel 15…24V dc Encoder / Counter
Configuration Data Data Type Default Value Valid Data Values
SS Counter Control SINT 0
SS Counter Reset BIT 0
0=Count Unchanged
1=Count Cleared
SS Counter Preset BIT 1
0=Count Unchanged
1=Count Set to Preset
SS Value Reset BIT 2
0=Count Unchanged
1=Count Cleared
Toentervaluesfrom+128to+255,usetheseconversionformulas:
DecimalPosition
DesiredDecimalPositionValue‐256=EnteredDecimalPositionValue.
Example:foradivisorof200,200‐256=‐56
GateInterval
DesiredGateIntervalValue‐256=EnteredGateIntervalValue.
Example:foraGate
Intervalof200,200‐256=‐56
Scalar
DesiredScalarValue‐256=EnteredScalarValue.
Example:foraScalarof128,128‐256=‐128