Sensor position of Prosilica GC cameras
Method of
Positioning:
Video alignment of photo sensitive sensor area into camera
front module.
(lens mount front flange)
Reference points: Sensor: Center of pixel area (photo sensitive cells).
Camera: Center of camera front flange (outer case edges).
Accuracy:
x/y ±400 µm (Sensor shift)
α
± 1
0
(Sensor rotation)