Specification Sheet

©2021 Ferguson Enterprises, LLC 0721 2964491
FERGUSON.COM/PROSELECT
Inline Descaling System
Product Specifications
PSWFDSAS20
Operating Recommendations
Please read installation instructions carefully and completely before
installing unit.
If copper lines are in service, you must passivate the lines for a
minimum of 3 weeks before installing the system. Do not use on a
closed loop system.
Install unit in a vertical, upright and level position.
Allow a minimum of 3" under the system for cartridge replacements.
Install on cold water lines only.
Proper maintenance of the water heater is required when water
heater quality does not meet EPA standards. Damage caused by
poor water quality is not covered under warranty. The following
table shows the maximum contaminant levels allowed. If you
suspect that your water is contaminated in any way, discontinue
use of the water heater and contact an authorized technician or
licensed professional.
Water Quality Guidelines
Contaminant Max Allowed
Total Hardness <45 grains (780 ppm CaCO3)
Aluminum .05–.2 mg/l
Chloride Up to 250 mg/l
Chlorine <3 ppm
Copper 1.3 ppm
Iron .5 mg/l
Manganese Up to .05 mg/l
Oil & H2S None allowed
pH 6.5-9.5
Polyphosphate None allowed
Salinity (Max) 35000 PPM
Sulfate Up to 250 mg/l
TDS Up to 500 mg/l
Zinc Up to 5mg/l
Replacement
Part Number Replacement Cycle
PSWFDSRCAS20 2 years
Pressure Drop
Flow rate Typical Pressure Drop
3 gpm 4-5 psi
4 gpm 6-7 psi
5 gpm 10 psi
7 gpm 19-20 psi
9 gpm 30 psi