ProSelect Force Hot Water Oil Boiler Installation Manual
3
106346-06 - 8/19
FORCE
Installation, Operating & Service Manual
DANGER
DO NOT store or use gasoline or other flammable vapors or liquids in the vicinity of this or any other
appliance.
WARNING
• Improper installation, adjustment, alteration, service or maintenance can cause property damage, personal
injury or loss of life. Failure to follow all instructions in the proper order can cause personal injury or death.
Read and understand all instructions, including all those contained in component manufacturers manuals
which are provided with the appliance before installing, starting-up, operating, maintaining or servicing this
appliance. Keep this manual and literature in legible condition and posted near appliance for reference by
owner and service technician.
• This boiler requires regular maintenance and service to operate safely. Follow the instructions contained in
this manual.
• Installation, maintenance, and service must be performed only by an experienced, skilled and
knowledgeable installer or service agency.
• All heating systems should be designed by competent contractors and only persons knowledgeable in the
layout and installation of hydronic heating systems should attempt installation of any boiler.
• Installation is NOT complete unless a pressure relief valve is installed into the 3/4" tapping located on supply
piping that was installed into boss on top of rear section - See "Packaged Boiler Assy - Trim & Controls" and
"Water Boiler Piping" Sections of this manual for details.
• It is the responsibility of the installing contractor to see that all controls are correctly installed and are
operating properly when the installation is complete including verifying that the limit sensor is fully installed.
Failure to properly install Limit Sensor may result in property damage, personal injury or loss of life due to
elevated operating temperatures and/or pressures.
• This boiler is suitable for installation on combustible flooring. DO NOT install boiler on carpeting.
• DO NOT tamper with or alter the boiler or controls.
• Inspect flueways at least once a year - preferably at the start of the heating season. The inside of the
combustion chamber, the vent system and boiler flueways should be cleaned if soot or scale has
accumulated.
When cleaning this boiler, take precaution to avoid damage to burner swing door insulation. If damaged, or if
there is evidence of previous damage, burner swing door insulation must be replaced immediately.
• Oil Burner and Controls must be checked at least once a year or as may be necessitated.
• DO NOT operate unit with jumpered or absent controls or safety devices.
• DO NOT operate unit if any control, switch, component, or device has been subject to water.
• Boiler materials of construction, products of combustion and the fuel contain alumina, silica, heavy metals,
carbon monoxide, nitrogen oxides, aldehydes and/or other toxic or harmful substances which can cause
death or serious injury and which are known to the state of California to cause cancer, birth defects and
other reproductive harm. Always use proper safety clothing, respirators and equipment when servicing or
working nearby the appliance.
!
!