Instructions / Assembly

Page 23 of 25
Supports Systems:
The support system for the liner should be considered by this
point in the install.
a. A support system such as below the breaching point in the
wall for the system to rest on.
b. A support system such as suspending guy wires from an
anchor plate at the chimney top affixed to guy bands around
the flex liner.
Z-VENT™ SMOOTHCORE TYPICAL INSTALLATION
1. Determine if the masonry chimney, factory built chimney or chase can accept the Z-Vent™ fitting that will connect
to the Smoothcore flex liner by measuring the dimension of the fitting that will be part of the flex liner system.
Allow for ½ inch (13mm) more than the dimension of the largest fitting for easy passage through the structure.
(see illustrations for optional installs)
.
Advisory: For the reasons of safety and quality of installation, the flex liner system should be installed with two persons,
one person lowering the liner from the top of the masonry chimney, while the other person pulls the liner down from
below.
2. Connect Smoothcore flex to the Z-Vent™ fitting and tighten
all connections.
3. Tie a guide rope to the flex liner above the male connector so
as to prevent the rope from slipping off and lower the rope in
the structure to the awaiting person down below.
4. Lower the fitting and flex through the chimney top opening
while the person below using the guide rope pulls the liner
down through to the breaching.
.
5. Remove the rope to align the fitting & condensate tube in
their final positions. Connect the breach pipe and tighten all
connections. Route the tube to a suitable condensate drain
or neutralizer.
Note: In cases where the structure is unable to accommodate
the dimensions of the fitting, the installers may seek an
alternate option of attaching the fitting through an enlarged
breach accessing the liner from the mechanical room.