Instructions / Assembly
V-2008-3
A
B
D
C
1
2
3
4
x.xx
x.xx
EMERSON
Appliance Solutions
TM
REVISIONS
REV. DESCRIPTION DATE BY APVD.
1
THIS WAS A PROCEDURE- STAMPING
REDRAW IN PRO/E. ECR 2290
05/07/09 PMO FMS
CONFIDENTIAL
ALL INFORMATION HEREIN STATED IS CONFIDENTIAL TO
AND PROPERTY OF EMERSON APPLIANCE SOLUTIONS -
EMERSON HEATING PRODUCTS AND MAY NOT BE
REPRODUCED IN WHOLE OR IN PART WITHOUT THE
EXPRESS WRITTEN PERMISSION OF SAME.
MUST COMPLY WITH EC DIRECTIVE 2002/95/EC, AND AMENDMENTS
THERETO, FOR RESTRICTION OF HAZARDOUS MATERIALS (ROHS).
1 Of 1
Critical to Regulatory Requirements
(x.xx=Cpk requirements)
Critical to Quality
(x.xx=Cpk requirements)
Angles: ±2°
Wattage: ±5%
Sheet:
1 223-893658-000 B
Unless otherwise specified, all
dimensions are in inches. Metric
equivalent shown in [ ].
Metric
±0.80
±0.25
±0.13
English
±.030
±.010
±.005
x.x
x.xx
x.xxx
Revision:Drawing no.:Size:
INSTALLATION INSTRUCTION SHEET
Third Angle Projection: Use
ANSI Y14.5-1994 to interpret
drawing. Do not scale drawing.
Title:General Tolerances:
Emerson Heating Products
05/07/09 FMS
Date:Approved by:Reference:
05/26/09 RER
Date:Checked by:
09/20/84 ED ESTES
Date:Drawn by:Material:
LS STYLE
1. Select the same element that is being
replaced. Check flange style, voltage
and watage.
2. Disconnect all electric power to tank.
3. Turn off cold water supply to tank.
4. Open hot water faucet to relieve pressure.
5. Drain water heater to a level below the
element being replaced.
6. Disconnect wires from heating element
and remove it from the tank.
7. Insert new element, making certain the
gasket is positioned properly.
8. If bolt-on type, tighten bolts evenly.
9. Connect wires to element and fill tank
with cold water. Note: make certain the
tank is full.
10. Open water faucets to expel any trapped
air in tank.
11. Turn on electric power supply.
TG STYLE
FTG STYLE
SG STYLE
FIT TO SIZE "A" SHEET PRINT OUT
PART NUMBER: 893658-001
INSTALLATION INSTRUCTION