Level (LFO 2 to LFO 1 Level)
This controls the modulation amount from the LFO 2 signal level to LFO 1’s Level. The result is amplitude modulation
(AM) of LFO 1.
Sync
With the Sync button on, every new LFO 2 cycle automatically restarts LFO 1.
Envelope
This is an AR (Attack-Release) envelope. The Envelope can be triggered from any of these four sources:
The Trig button, see “Trig”.
•LFO 2, see “LFO 2 Trig”.
Envelope Gate In modulation input on the rear panel, see “Envelope Gate In”.
MIDI Note On from a connected MIDI keyboard.
The Envelope can modulate the Levels and Rates of LFO 1 and/or LFO 2.
! If the envelope is retriggered before all envelope stages are completed, the envelope will simply restart at the
current level (similar to how a monophonic synthesizer works).
LFO 2 Trig
With the LFO 2 Trig button on, the Envelope is automatically synced by the LFO 2 signal. This means that every time
LFO 2 begins a new cycle, the envelope is triggered.
Trig
This is a non-latching gate button which gates/triggers the envelope.
Attack and Release
The attack and release times of the envelope when the gate opens/closes are set with these knobs. For a gated
effect set both controls to zero and control the gate time with the Trig button, CV Gate In modulation input or MIDI
Notes. You can also let LFO 2 trig/gate the envelope as described above.
Range: 0.1ms-3.00s (Attack) and 0.0ms-10.00s (Release)