SHOWER FAUCET Installation Manual Cust omer Service:pr ooxus@gmai l .
1、Installation Precautions 1.When you open the product packaging, please check the product and accessories at first. If there is any discrepancy, please contact the company or our distributor immediately. 2.The hot and cold water supply pipe of the faucet must be properly connected. When facing the front of the faucet, the hot water supply is on the left and cold water supply is on the right. Incorrect connection will cause permanent damage to the cartridge. 3.
、Two function concealed faucet accessories list 11 13 12 10 9 4 5 1 2 3 ( Not I ncl uded) Quantity Description Number 1 control valve 1 Protective cover 2 0 cover board 3 1 4 1 diverter handle on/off handle 5 1 Shower hose 6 1 7 1 Elbow with hook Handle shower 8 1 9 Shower head 1 10 1 Shower arm 11 Cover board 1 12 Screw set 1 Allen key 13 1 (78"~88") 47"~63" 36"~40" 5.2" 7.5" 2.68" Reference size 6.7" 2.68" 2.8" 10.5" 5.
、Technical drawing of product Unit:inch 1/2-14NPT 2.8" (78"~88") 1.8"~2.4" 36"~40" 2-1/2-14NPT 47"~63" 2-1/2-14NPT 5.2" 7087" 2.68" 6" Reference size 1/2-14NPT 3 6.7" 11" 2.68" 5.
、Technical drawing of drilling size 1、The size of the embedded box that needs to be drilled is 5.3"*6.7". (78"~88") 47"~63" 36"~40" 5.2" 7.5" 2.68" Reference size 6.7" 2.8" 10.5" 2.68" 5. 3" 2、The depth of the embedded box is 1.8"-2.2". It's better to drill the depth of 1.8"for blank wall. 2.2" 1.
、Pipe connection 1、Please drill the holes on the wall for the main body embedded part, hot and cold water inlet pipes as well as shower arm connection pipes according to the basic product dimension drawing as below. 6.7" 2.68" 2、Please make hot and cold water inlet pipe, the mixed water outlet pipe connect with control valve,and tighten with the wrench (78"~88") 47"~63" 36"~40" 5.2" 7.5" 2.68" Reference size 2.8" 10.5" 5.
、Water testing and sealing testing 1、After the pipe connection is completed, open the protective panel and cover, and then open the cartridge, flush the pipeline; then close the cartridge to check the pressure resistance and sealing performance of the pipeline, make sure there are no leakage. 2、Block each outlet pipe with a stopper then open the cartridge to check if the pipe joint is well-sealed and the pipe condition under pressure to ensure no leakage.
、The procedure of sealing the wall Use a parallel ruler to measure the flatness of the embedded box casing and the vertical wall surface. If the wall surface is not flat, it should be patched to ensure the embedded box casing and vertical wall angle meets at nearly ideal angle of 90, then lay the tile decoration.
、Installation of control valve 1、Take off the protective panel and cover 2、The decorative panel and the handle are connected to the control valve as shown below sequence.
、Shower sets installation
、Handle shower installation 10
1 2、Product reparation If the cartridge is worn out which cause leakage, please turn off the water source. Remove the handle, panel, and decorative cover in sequence, remove the gland with a wrench, then take out the cartridge and copper sleeve. Repair or replace the new cartridge, then install it again in sequence. 1 3、Clearance and Maintenance In order to keep the faucet appearance smooth and good performance, please follow the below steps to clean and maintain the faucet.