Operation Manual
INSTALLATION
1. The atmosphere
The battery should be charged in an area with adequate because it may emit
explosive gases. Be sure that there is enough space around the charger. This is
important for the air circulation, for cooling of the charger and release of gases
emitted.
The GBC 100 may not be used outdoors.
Important
do not charge when there is a fuel leak or fuel is evaporating.
when the charger is to be used in an aluminium or steel ship/vessel, it must
be insulated by suspension. That is, in order to avoid electrolysis, the casing
of the charger may not be in contact with the ship.
2. Wire thickness
The trailing cables are not delivered with the GBC 100. The following schedule may
be used to calculate the wire thickness (single).
wire length up to 3 meters
charge current wire thickness (single)
15 Amp 6 mmq
20 Amp 6 mmq
25 Amp. 10 mmq
30 Amp. 10 mmq
35 Amp. 16 mmq
3.Mounting
The charger can be mounted with the delivered mounting- material.
10