Chapter 8: Troubleshooting
275
Battery capacity is normal Normal.
Battery is discharging Battery is undergoing reconditioning.
Battery is charging Battery is being recharged.
Battery reconditioning is
complete
Battery reconditioning is finished.
Battery is malfunctioning Run battery reconditioning. See page 114 or
page 160. If this message reappears, replace the
battery.
Battery reconditioned
successfully
Battery reconditioning is finished.
Battery reconditioning has
failed
Replace the battery. See page 224.
Battery is reaching end of
life
Replace the battery. See page 224.
Battery is removed The battery was disconnected or removed. Reinstall
the battery. See page 224.
Battery charging failed Replace the battery. See page 224.
Battery reconditioning
started
Battery reconditioning has begun.
Battery recondition
terminated
The battery was disconnected or removed during
reconditioning. Reinstall the battery. See page 224.
Blowers
Blowers have started Normal.
Blowers have stopped Verify that the cooling unit is properly installed. If the
blower still does not turn, replace the blowers. See
page 219.
Blower speed is
increased
Check the VTrak for overheating. See page 295.
Blower speed is
decreased
Temporary overheat condition was corrected.
Blowers are NOT
functioning
Replace the blowers. See page 219.
Blowers have been
inserted
Normal.
Reported Event Corrective Action