158
Managing the Enclosure
Enclosure Management includes the following functions:
• Viewing Enclosure Information (page 158)
• Viewing Power Supply Status (page 158)
• Locating a Power Supply (page 159)
• Viewing Blower Status (page 159)
• Viewing Voltage Sensor Status (page 159)
• Viewing Temperature Sensor Status (page 159)
• Setting Temperature Thresholds (page 160)
• Checking the Batteries (page 160)
• Reconditioning a Battery (page 161)
• Locating an Enclosure (page 161)
• Viewing Enclosure Topology (page 161)
Viewing Enclosure Information
Enclosure Management includes information, status, settings and location. To
access Enclosure Management:
1. From the Main Menu, highlight Subsystem Management and press Enter.
2. Highlight Enclosure Management and press Enter.
To access FPU VPD information (vital product data on field replaceable units),
highlight FPU VPD Information and press Enter.
To access the current status of the power supplies, blowers, temperature or
voltage sensors, highlight the item you want and press Enter.
Viewing Power Supply Status
To view the status of the power supplies:
1. From the Main Menu, highlight Subsystem Management and press Enter.
2. Highlight Enclosure Management and press Enter.
3. Highlight Power Supplies and press Enter.
The screen displays the operational and fan status of VTrak’s two power
supplies. If any status differs from normal or the fan speed is below the Healthy
Threshold value, there is a fan/power supply malfunction. See “Replacing a
Power Supply” on page 218.