Product manual
Chapter 3: Setup
This chapter covers the following topics:
• Connecting the Power (below)
• Setting-up the Serial Connection (page 44)
• VTrak Default IP Addresses (page 45)
• Choosing DHCP or a Static IP Address (page 45)
• Setting-up VTrak with the CLI (page 47)
• Setting-up VTrak with the CLU (page 55)
• Logging into WebPAM PROe (page 60)
• Creating Disk Arrays and Logical Drives (page 62)
• Enabling LUN Mapping and Masking (page 67)
• Logging out of WebPAM PROe (page 68)
Connecting the Power
Plug in the power cables and turn on the switches on both power supplies.
When the power is switched on, the LEDs on the right handle light up.
When boot-up is finished and the VTrak is functioning normally:
• Power, FRU, and Logical Drive LEDs display steady green.
• Each controller activity LED flashes green when there is activity on that
controller.
• The controller heartbeat LED blinks green once per second for five seconds,
goes dark for ten seconds, then blinks green once per second for five
seconds again.
Steady means the LED is on.
Blinking means a regular on/off pattern.
Flashing means an intermittent and irregular on/off pattern.
See page 42, Figure 1.
Important
If you have a SAN, DAS, or Cascade with JBOD Expansion,
always power on the JBOD expansion units first.