Product manual

Chapter 8: Troubleshooting
279
Synchronization is
queued
Synchronization is already running on another logical
drive in the same array.
Synchronization is
stopped internally
Synchronization stopped because the disk array was
deleted or removed.
System (VTrak)
The system is started The VTrak has been started.
The system is stopped The VTrak was shut down.
Transition
Transition is started Result of settings or user action. Normal.
Transition is completed Normal.
Transition is paused Transition paused because of user intervention,
schedule or a higher priority background activity.
Transition is resumed Transition has resumed again after a pause.
Transition is stopped Transition stopped because of user intervention or
the logical drive was deleted.
Transition was switched
to rebuild
Transition changed to rebuild because the logical
drive went critical.
Watermark
Migration has detected/
cleared stale NV
Watermark
Watermarks are progress markers left as the result of
interrupted RAID migrations. If the watermark was
cleared, migration should finish.
Array was incomplete due
to missing NV Watermark
RAID migration was interrupted by a shutdown. If
array is online, try migration again. See page 135. If
array is offline, delete and recreate array. See
page 130 and page 128.