Product manual
Chapter 4: Management with WebPAM PROe
119
Buzzer
The Enclosure–Buzzer tab enables you to change audible settings for the VTrak
subsystem enclosure. VTrak's audible alarm has four signals:
• Beep. Beep. Beep: Indicates that one or more Logical Drives is Rebuilding.
• Beep-beep, beep-beep, beep-beep: Indicates that one or more Logical
Drives is Critical.
• Beep-beep-beep, beep-beep-beep: Indicates a problem with an FRU.
• 10 second continuous beep: Indicates that one or more Logical Drives is
Offline.
Silence Buzzer
To silence the Buzzer for the current event only, do the following:
1. Click the Subsystem icon in Tree View.
2. Click on the Enclosures icon.
3. Click on the Enclosure icon.
4. Click on the Buzzer tab in Management View.
5. From the Buzzer tab dropdown menu, select Settings.
6. Uncheck the Buzzer Sounding box.
7. Click the Submit button.
The Buzzer goes silent for the current event. If the Buzzer is enabled, it will
sound again when the next event happens.
Change Buzzer Settings
To change Buzzer settings, do the following:
1. Click the Subsystem icon in Tree View.
2. Click on the Enclosures icon.
3. Click on the Enclosure icon.
4. Click on the Buzzer tab in Management View.
5. From the Buzzer tab dropdown menu, select Settings.
6. Check the Buzzer Enabled box to enable the buzzer for all events.
7. Check the Buzzer Sounding box to enable the buzzer the current event only.
8. Click the Submit button.
The setting is changed immediately.
Physical Drives
The Physical Drives–Information tab provides information about the physical disk
drives installed in the VTrak subsystem enclosure, including: