Product manual

Chapter 4: Management with WebPAM PROe
117
Enclosure Settings
The Enclosure–Settings tab enables you to make settings for certain components
of the VTrak subsystem enclosure. To make Enclosure settings:
1. Click the Subsystem icon in Tree View.
2. Click on the Enclosures icon.
3. Click on the Enclosure icon.
4. Click on the Settings tab in Management View.
5. Enter a polling interval (15 to 255 seconds) in the Polling Interval field.
6. Enter a value in the Enclosure Warning Temperature Threshold field (45°C is
the default)
7. Enter a value in the Enclosure Critical Temperature Threshold field (51°C is
the default)
8. Enter a value in the Controller Warning Temperature Threshold field (63°C is
the default)
9. Enter a value in the Controller Critical Temperature Threshold field (68°C is
the default)
10. Click the Submit button.
The changes take effect immediately.