Vess R2000 Series Product Manual Promise Technologies
woRkIng wIth SoftwARe MAnAgeMent (clu)
Software Management includes the following functions:
• “Making Email Settings (CLU)” on page 512
• “Making SLP Settings (CLU)” on page 513
• “Making Telnet Settings (CLU)” on page 513
• “Making SSH Settings (CLU)” on page 514
• “Making SNMP Settings (CLU)” on page 515
• “Managing SNMP Trap Sinks (CLU)” on page 516
• “Making Netsend Settings (CLU)” on page 517
• “Managing Netsend Recipients (CLU)” on page 518
MakiNg eMail settiNgs (Clu)
By default, Email service is set to Automatic and its normal status is Started.
To make Email service settings:
1. From the Main Menu, highlight Additional Info and Management and press Enter.
2. Highlight Software Management and press Enter.
3. Highlight Email and press Enter.
4. Highlight Startup Type and press the spacebar to toggle between Automatic and Manual.
5. Highlight the following and press the backspace key to erase the current value, then type the new value:
• SMTPserverIPaddressorservername
• ServerPortnumber(25isthedefault)
6. Highlight Authentication and press the spacebar to toggle between Yes and No.
IfyouselectedYes,typeinaUsernameandPasswordintheeldsprovided.
7. The following items are optional but recommended. Highlight and press the backspace key to erase the
current value, then type the new value:
• Sender’semailaddress
• SubjectLinefortheemailmessage