Product Manual Manage with CLU
MakiNg ups settiNgs (Clu)
These settings control how the Vess R2000 subsystem detects the UPS unit and responds to data reported by
the UPS unit.
To make UPS settings:
1. From the Main Menu, highlight Additional Info and Management and press Enter.
2. Highlight UPS Management and press Enter.
3. Highlight UPS Settings and press Enter.
4. Perform the following actions as required:
• VerifytheCurrentUPSCommunicationmethod.SeeNote1:
SNMP–Networkconnection.
Serial–Serialconnection.
Unknown–Noconnection.
• ChooseaDetectionSettingfromthedrop-downmenu:
Automatic–Default.IfaUPSisdetectedwhenthesubsystemboots,thesettingschanges
toEnable.
Enable–MonitorsUPS.Settingschanges,reportswarnings,andlogsevents.
Disable–MonitorsUPSonly.
• TypevaluesintotheThresholdelds.SeeNote2:
RunningTimeRemainingThreshold–Actualtimebelowthisvalueresetsadaptivewrite-
backcachetowritethrough.
WarningTemperatureThreshold–Actualtemperatureabovethisvaluetriggersawarning
andlogsanevent.
LoadingRatioThreshold–Actualloadingratio(percentage)abovethisthresholdtriggersa
warningandlogsanevent.SeeNote3.
BatteryChargeRemainingThreshold–Reservecapacitybelowthispercentagetriggersa
warningandlogsanevent.
• ForUPSunitswithnetworkcards,typetheIPaddressesor
DNSnamesineldsUPS1andUPS2.SeeNote4.
5. Press
Control-A
to save your settings.
Note 1: Vess R2000 supports multiple UPS units using network or serial connections, but not a
combination of both methods.
Note 2: Detection Setting must be set to Auto. If a UPS is detected, the settings changes to Enable.
Note 3: The maximum recommended Loading Ratio varies among models of UPS units. The general range