Product Manual Manage with CLU
• OutStandingR2T–MaximumnumberofR2TPDUsthetarget
canhaveoutstandingforasingleiSCSIcommand.
• MaxBurstLen–Maximumlengthofasoliciteddatasequenceinbytes.
• DefTimeToWait–Afteradroppedconnection,thenumberof
secondstowaitbeforeattemptingtoreconnect.
• DefTimeToRetain–Numberofsecondsaftertimetowait
(above)beforereassigningoutstandingcommands.
• HeaderDigest–Enablestheuseofheaderdigest(CRC).Enabledordisabled.*
• DataDigest–Enablestheuseofadatadigest(CRC).Enabledordisabled.*
• UniCHAPAuthen–Uni-directional(peer)CHAPauthentication,enabledordisabled.*
• BiCHAPAuthen–Bi-directional(local)CHAPauthentication,enabledordisabled.*
• FirstBurstLen–Firstburstlengthinbytes.
• AssignedPortals–Portalsassignedtothistarget.
• NOP-In:CheckiSCSIconnectionstatus*
Items marked with an asterisk (*) are adjustable under “Making iSCSI Target Settings (CLU)” on page
475.
MakiNg isCsi target settiNgs (Clu)
To make target settings:
1. From the Main Menu, highlight iSCSI Management and press Enter.
2. Highlight iSCSI Targets and press Enter.
The list of
iSCSI Targets displays.
3. Highlight the target you want to change and press Enter.
The target information screen displays.
4. Highlight iSCSI Target Settings and press Enter.
5. Make new settings as needed.
• Optional.HighlightTargetAliasandtypeanaliasintotheeldprovided.
• HighlighteachitemandpresstheSpacebartotogglebetweenEnableandDisable.
• HeaderDigest–Addsaheaderdigest(CRC).
• DataDigest–Addsadatadigest(CRC).
• UniCHAPAuthen–Enablesuni-directionalCHAPauthentication.
• BiCHAPAuthen–Enablesbi-directionalCHAPauthentication.
Authenticationrequiresapre-existingCHAP.