Vess R2000 Series Product Manual Promise Technologies
ViewiNg a list oF isCsi targets (Clu)
A target is a logical drive on the Vess R2000 subsystem.
The default target exposes all logical drives and is associated with all portals on the subsystem.
To view a list of iSCSI targets:
1. From the Main Menu, highlight iSCSI Management and press Enter.
2. Highlight iSCSI Targets and press Enter.
The list of iSCSI Targets displays.
• ID–Targetnumber.0isthedefaulttarget.
• Alias–Userassignednameofthetarget
• AssignedPortals–portalsassignedtothetarget
ViewiNg isCsi target iNForMatioN (Clu)
To view information for an iSCSI target:
1. From the Main Menu, highlight iSCSI Management and press Enter.
2. Highlight iSCSI Targets and press Enter.
The list of
iSCSI Targets displays.
3. Highlight the target you want to change and press Enter.
The target information screen displays. Information includes:
• TargetName–iSCSIqualiedname(iqn)ofthistarget.
• TargetAlias–Maximumof32characters.Useletters,numbers,
spacebetweenwords,andunderscore.Analiasisoptional.*
• TargetStatus–Upordown.
• ErrorRecovLevel–Errorrecoverylevelsupported.
• ImmediateData–Enablestheinitiatortosendunsolicited
datawiththeiSCSIcommandPDU.
• MaxConnection–Maximumnumberofconnections.
• DataPDUInOrder–EnablesplacementofdatainPDUorder.
• InitialR2T–Allowsinitiatortobeginsendingdatatoatarget
withoutreceivingareadytotransfercommand.
• DataSeqInOrder–Enablesplacementofdatainsequentialorder.