Vess R2000 Series Product Manual Promise Technologies
prepariNg the disk array For traNsport (Clu)
To run the Transport function on a disk array:
1. From the Main Menu, highlight Disk Array Management and press Enter.
2. Highlight the disk array you want and press Enter.
3. Highlight Transport and press Enter.
4. PressYtoconrm.
rebuildiNg a disk array (Clu)
Before you can rebuild, you must have a replacement or target physical drive of adequate capacity for your
disk array.
To rebuild a disk array:
1. From the Main Menu, highlight Disk Array Management and press Enter.
2. Highlight the disk array you want and press Enter.
3. Highlight Background Activities and press Enter.
4. Highlight Rebuild and press Enter.
Default source and target drives are shown with possible alternative choices.
5. To choose different drive, highlight the drive, press the backspace key to remove the current number,
then type a new number.
6. Highlight Start and press Enter.
For rebuild rate, see “Making Background Activity Settings” on page 494.
ruNNiNg Media patrol oN a disk array (Clu)
Media Patrol is a routine maintenance procedure that checks the magnetic media on each disk drive. If Media
Patrol encounters a critical error, it triggers PDM if PDM is enabled on the disk array.
See
“EnablingMediaPatrol,PDM,PowerManagement-DiskArray(CLU)”onpage447.