reCoNditioNiNg a battery (Clu)
To recondition the subsystem battery:
1. From the Main Menu, highlight Subsystem Management and press Enter.
2. Highlight Enclosure Management and press Enter.
3. Highlight the enclosure you want and press Enter.
4. Highlight Batteries and press Enter.
5. Highlight the battery you want to recondition and press Enter.
6. Highlight Start Reconditioning and press Enter.
7. PressYtoconrm.
Reconditioning fully discharges, then fully recharges the battery. During reconditioning, if the Adaptive
Writeback Cache function is enabled, the controller cache is set to
Write Thru. After reconditioning, the
cache is reset to
Write Back. See “Making Controller Settings (CLU)” on page 422.
loCatiNg aN eNClosure (Clu)
This feature helps you identify the physical Vess R2000 enclosure you are working with through the CLU.
1. From the Main Menu, highlight Subsystem Management and press Enter.
2. Highlight Enclosure Management and press Enter.
3. Highlight the enclosure you want and press Enter.
4. Highlight Locate Enclosure and press Enter.
The LEDs on the front of the Vess R2000 blink for one minute.