User Manual

Table Of Contents
336
Vess R2000 Series Product Manual Promise Technologies
enclosure
Usage
enclosure[-a<action>]-v
enclosure-amod-s<listofsettings>
enclosure-alocate[-t<FRUtype>-f<FRUid>]
Summary
The enclosure command provides status and information about the various components of
the enclosure unit. It is also used to set thresholds for temperature and polling. In addition
when using the -v option all VPD (Vendor Provided Data) will be displayed.
Options
-a<action> Whichactiontoperform.
list (Default)Displaysinformationandstatusoftheenclosure.
mod Allowstheusertomodifysettingswhencoupledwiththe-sswitch.
locate AllowstheusertolocateanenclosurebyashingLEDs
-e<enclid> EnclosureID.Thedefaultvalueis1ifunspecied.
 Forlistaction,thedefaultisforallenclosuresifunspecied.
-s“<option>=<value>” UsedtospecifywhichEnclosuresettingstochange.
tempwarning= (56-60)Temperature,displayedinCelsius,thattheSEPwill
considerasawarningthreshold.
tempcritical= (61-73)Temperature,inCelsius,thattheSEPwillconsiderasa
criticalthreshold.
ctrltempwarning= (76-80)Controllertemperature,displayedinCelsius,thatthe
controllerwillconsiderasawarningthreshold.