Vess R2000 Series Product Manual Promise Technologies
cong
Usage
cong-aauto
cong-aexpr[-ry|n][-cy|n][-py|n][-my|n][-sy|n][-t<AppType>][-l<NumLd>]
Summary
The cong command has two options, Automatic (auto) and Express (expr).
Automatic conguration takes all available uncongured physical drives to create an
optimized disk array following a default set of parameters. There are no options.
Express conguration takes your input, creates one or two arrays, and spreads their capacity
evenly over all of the logical drives that you specify.
The redundancy option creates redundant logical drives (RAID 1, 10, 1E, 5, 50, 6, or 60).
The capacity option enables optimizes the logical drives for capacity. The performance
option optimizes the logical drives for performance.
If you choose all three options, redundancy gets highest priority and capacity gets lowest
priority.
Note that you cannot combine HDDs and SSDs in the same disk array. If your system
has both type of drives, it will create separate disk array/logical drive sets for each type of
physical drive.