The array command is the main command for performing advanced conguration and
maintenance tasks on disk arrays.
This command is used to list, create, modify, delete, and locate disk arrays. Also to add and
delete logical drives.
Note that you cannot mix Hard Disk Drives (HDD) and Solid State Drives (SSD) in the same
disk array.
Options
-a<action> Speciestheactiontoperform.
list (Default)Displaysasummaryofalloraspecicoraspecied
numberofarrays.
add Add/createanarrayandpossiblysomelogicaldrives
 atthesametime.
addld Add/createalogicaldrivetoanarraythatalready
 exists.
delld Deleteanexistinglogicaldrivefromanarray.
mod Modifysettingsofanexistingarray.
del Deleteanexistingarrayandallitsassociatedlogicaldrives.
locate Locateanarray.
accept Acceptstheconditionofanincompletearray.Therearetwo
conditionsthatwillcausethearraytoreportasincomplete:
• MissingDrive,i.e.whenoneormoredrivesaremissinginthearray.
• MissingNVRAMWatermark,theNVRAMWatermarkofmigration
notfoundonthecontroller,howevertheDDFonthearray
indicatesthemigrationisinprogress.
Whentheeitheroftheaboveconditionhappens,allthelogicaldrivesonthe