Table Of Contents
228
Vess R2000 Series Product Manual Promise Technologies
Port information includes:
MakiNg FC port settiNgs
To make Fibre Channel port settings:
1. Click the Device tab.
2. Click the FC Management icon.
3. Click the Port tab.
4. Click the FC port you want to access and click the Settings button.
5. Make these changes as required:
• Chooseaconguredlinkspeedfromthedrop-downmenu.
ThechoicesareAuto(default),2Gb/s,4Gb/s,and8Gb/s.
• Chooseatopologyfromthedrop-downmenu.
• EnteraHardALPAintheeldprovided.
Enter255todisableHardALPA.
6. Click the Save button.
POrt setting infOrMAtiOn
The table below shows the type of attached topology you achieve based on your connection type and the
conguredtopologyyouselect.
Example1:IfyouconnecttheVessR2600toanFCswitchandchooseNL-Porttopology,youcreateaPublic
Loop attached topology.
Example2:IfyouhaveaPoint-to-Pointattachedtopology,youmadeadirectconnection(noFCswitch)and
selected N-port topology.
• FC Port ID - FC port number
• State - Link status
• Topology Attached
• WWNN - World Wide Node Name
• Fabric WWPN
• Current Speed
•
ConguredLinkSpeed
• Hard ALPA
• Location - Controller ID number
•
Identier-(hexadecimal)
• Alias WWPN -
• WWPN - Worldwide Port Name
• Fabric WWNN
• Link Type
•
ConguredTopology