Product Manual WebPAM PROe - System Conguration
MakiNg ups settiNgs
These settings control how the Vess R2600 subsystem detects the UPS unit and responds to data reported by
the UPS unit.
To make UPS settings:
1. Click the Device tab.
2. Click the UPS icon.
3. Click the UPS Settings button.
4. Perform the following actions as required:
• VerifytheCurrentUPSCommunicationmethod.SeeNote1:
SNMP–Networkconnection.
USB
Unknown
–Noconnection.
• ChooseaDetectionSettingfromthedrop-downmenu:
Automatic–Default.IfaUPSisdetectedwhenthesubsystemboots,thesettings
changestoEnable.
Enable–MonitorsUPS.Settingschanges,reportswarnings,andlogsevents.
Disable–DoesnotmonitorUPS.
• TypevaluesintotheThresholdelds.SeeNote2:
Running Time Remaining Threshold–Actualtimebelowthisvalueresets
adaptivewritebackcachetowritethrough.
Warning Temperature Threshold–Actualtemperatureabovethisvaluetriggersa
warningandlogsanevent.
Loading Ratio Threshold–Actualloadingratio(percentage)abovethisthreshold
triggersawarningandlogsanevent.SeeNote3.
• ForUPSunitswithnetworkcards,typetheIPaddressesor
DNSnamesineldsUPS1andUPS2.SeeNote4.
5. Press Submit to save your settings.
Note1:VessR2600supportsmultipleUPSunitsusingnetworkorUSBconnections,butnotacombination