Product manual

VessRAID 1000f, 1000i, 1000s Series Product Manual
372
If the Controller Status LED is amber, restart the VessRAID. See “Restarting the
Subsystem” on page 134 (WebPAM PROe) or page 288 (CLU).
If the Controller Status LED continues to display amber after startup, contact
PROMISE Technical Support. See page 411.
The Dirty Cache LED flashes during input/output operation. If the LED shines
amber and the power is off, there is unsaved data in the cache. Do NOT power
down the VessRAID while this LED is on. See “Browser Does Not Connect to
WebPAM PROe” on page 406 for more information.
If the Battery LED is amber or red, try reconditioning the battery. See
“Reconditioning a Battery” on page 143 or page 224. If the condition returns,
replace the battery.
If a Fan LED is amber or red:
1. Identify the malfunctioning fan. See “Viewing Enclosure Information” on
page 141 or page 221.
2. Replace the fan. See “Replacing a Cooling Fan” on page 321.
Also see “Enclosure Problems” on page 400.
LEDs
State
Dark Green Amber Red Blinking
Controller
Status
no power OK Error
Malfunction
at start-up
Green:
Activity
Dirty Cache
No data in
cache
Unsaved
data
in cache
Amber:
Unsaved
data
in cache
Battery Not
detected or
Not installed
OK
Backup
capacity
below 72
hours
No power to
controller
cache
Fan
Not
detected
OK
One fan
turning too
slowly
Multiple
fans turning
too slowly
USB Ports
No device
detected
Device
detected
Failed data
transfer
Amber:
Activity
SAS OUT
Port
No
connection
Port
connected
——
Green:
Activity