Product manual
VessRAID 1000f, 1000i, 1000s Product Manual
356
RAID 6
A RAID 6 Source logical drive can migrate to the following Target logical drives:
RAID 10
A RAID 10 Source logical drive can migrate to the following Target logical drives:
Target Requirements
RAID 6 Add physical drives. 32 maximum.
RAID 60 8 physical drives minimum, 32 per axle maximum.
If existing physical drives have no unused space, add 1 or
more physical drives.
Target Requirements
RAID 0 None.
RAID 1E None.
RAID 3
RAID 5
3 physical drives minimum, 32 maximum.
RAID 10 must have less than 32 physical drives.
RAID 6 4 physical drives minimum, 32 maximum.
RAID 10 must have less than 32 physical drives.
If existing physical drives have no unused space, add 1 or
more physical drives.
RAID 10 Add physical drives.
Even number of physical drives.
RAID 30
RAID 50
6 physical drives minimum, 32 per axle maximum.
RAID 60 8 physical drives minimum, 32 per axle maximum.
If existing physical drives have no unused space, add 1 or
more physical drives.