Product manual

VessRAID 1000f, 1000i, 1000s Product Manual
352
RAID 0
A RAID 0 source logical drive can migrate to the following target logical drives:
Target Requirements
RAID 0 Add physical drives.
RAID 1 2 physical drives only.
Only a single-drive RAID 0 can migrate to RAID 1 by adding 1
physical drive.
RAID 1E 3 or more physical drives.
If existing physical drives have no unused space, add 1 or
more physical drives.
RAID 3
RAID 5
3 physical drives minimum, 32 maximum.
RAID 0 must have less than 16 physical drives.
If existing physical drives have no unused space, add 1 or
more physical drives.
RAID 6 4 physical drives minimum, 32 maximum.
If existing physical drives have no unused space, add 1 or
more physical drives.
RAID 10 4 physical drives minimum.
Even number of physical drives.
If existing physical drives have no unused space, add 1 or
more physical drives.
RAID 30
RAID 50
6 physical drives minimum, 32 per axle maximum.
If existing physical drives have no unused space, add 1 or
more physical drives.
RAID 60 8 physical drives minimum, 32 per axle maximum.
If existing physical drives have no unused space, add 1 or
more physical drives.