Product manual
VessRAID 1000f, 1000i, 1000s Series Product Manual
8
Current (maximum), cont.
1730i/s and 1720i/s: 6A @ 100 VAC or 3 A @ 240 VAC current rating with one
power cord
1840f/i/s+: 8 A @ 100 VAC or 4 A @ 240 VAC current rating with two power cords
1830i/s+: 6A @ 100 VAC or 3 A @ 240 VAC current rating with two power cords
1720i+: 6A @ 100 VAC or 3 A @ 240 VAC current rating with one power cord
Power Consumption
1840f, 1840f+: without disk drives, 51.3 W; with 16 disk drives, 241.8 W
1740i, 1840i, 1840i+: without disk drives, 72.3 W; with 16 disk drives, 242.8 W
1740s, 1840s, 1840s+: without disk drives, 59.9 W; with 16 disk drives, 263.2 W
1730i, 1830i, 1830i+: without disk drives, 82.2 W; with 12 disk drives, 218.6 W
1730s, 1830s, 1830s+: without disk drives, 58.3 W; with 12 disk drives, 238.5
1720i, 1820i, 1720i+: without disk drives, 73.2 W; with 8 disk drives, 167.3 W
Temperature
Normal conditions:
5° to 40°C operational (-40° to 60°C non-operational)
Conditions of running SAS disk drives with one failed cooling fan:
5° to 35°C operational (-40° to 60°C non-operational)
Relative Humidity
95 percent maximum
Vibration
Random, 0.21 grms, 5-500 Hz, 30 Mins, X, Y, Z axis.
Dimensions (H x W x D)
1840f/i/s: 13 x 45 x 46 cm (5.1 x 17.7 x 18.1 in)
1830i/s and1820i/s: 8.8 x 45 x 46 cm (3.5 x 17.7 x 18.1 in)
1740i/s: 13 x 45 x 46 cm (5.1 x 17.7 x 18.1 in)
1730i/s, 1720i: 8.8 x 45 x 46 cm (3.5 x 17.7 x 18.1 in)
1840f/i/s+: 13 x 45 x 46 cm (5.1 x 17.7 x 18.1 in)
1830i/s+: 8.8 x 45 x 46 cm (3.5 x 17.7 x 18.1 in)
1720i+: 8.8 x 45 x 46 cm (3.5 x 17.7 x 18.1 in)