Chapter 6: Management with the CLU
249
Wake on LAN must be enabled to power off and power on the VessRAID
NAS from SmartNAVI. See “Powering On a NAS Device” on page 187.
7. Press Ctrl-A to save your settings.
Making iSCSI Port Settings
VessRAID iSCSI models have four iSCSI ports. VessRAID FC models have two
iSCSI ports. You must make network settings to each iSCSI port individually.
Before you change settings, please see “Choosing DHCP or a Static IP Address”
on page 42.
To make changes to the iSCSI Port settings:
Making Automatic Settings
1. From the Main Menu, highlight Network Management and press Enter.
2. Highlight the iSCSI port and press Enter.
3. Highlight NetMgmt iSCSI Port X Settings and press Enter
4. Highlight DHCP and press the spacebar to toggle to Enable.
5. Highlight TCP Port Number to change the entry.
3260 is the default and recommended for most applications.
6. Press Ctrl-A to save your settings.
Making Manual Settings
1. From the Main Menu, highlight Network Management and press Enter.
2. Highlight the management port and press Enter.
3. Highlight NetMgmt Ethernet Port Settings and press Enter
4. Highlight DHCP and press the spacebar to toggle to Disable.
5. Highlight each of the following and press the backspace key to erase the
current value, then type the new value.
• IP Address
• Subnet Mask
• Default Gateway IP Address
6. Highlight TCP Port Number to change the entry.
3260 is the default and recommended for most applications.
7. Press Ctrl-A to save your settings.
Creating a Link Aggregation Entry
Link aggregation combines multiple network ports in parallel to increase link
speed and to provide redundancy for high availability. This feature enables you to
aggregate the iSCSI data ports on your subsystem.