Battery is discharging Battery is undergoing reconditioning.
Battery is charging Battery is being recharged.
Battery reconditioning is
complete
Battery reconditioning is finished.
Battery is malfunctioning Run battery reconditioning. Run battery
reconditioning. See page 94 (WebPAM PROe) or
page 143 (CLU). If this message reappears, replace
the battery.
Battery reconditioned
successfully
Battery reconditioning is finished.
Battery reconditioning has
failed
Replace the battery. See page 228
Battery is reaching end of
life
Replace the battery. See page 228.
Battery is removed The battery was disconnected or removed. Reinstall
the battery. See page 228
Battery charging failed Replace the battery. See page 228.
Battery reconditioning
started
Battery reconditioning has begun.
Battery recondition
terminated
The battery was disconnected or removed during
reconditioning. Reinstall the battery. See page 228.
Blowers
Blowers have started Normal.
Blowers have stopped Verify that the fans are properly installed. If they still
does not turn, replace the fan. See page 226.
Blower speed is
increased
Check the VessRAID for overheating. See page 296.
Blower speed is
decreased
Temporary overheat condition was corrected.
Blowers are NOT
functioning
Replace the fans. See page 226.
Blowers have been
inserted
Normal.
Blowers have been
removed
Reinstall the fan. If the fan does not turn, replace it.
See page 226.