Product manual
Chapter 9: Troubleshooting
277
Event Notification Response
When you choose Event Notification, WebPAM PROe sends popup and/or email
messages regarding its status. The messages you see depend on your
notification selection and what is currently happening in the VessRAID. See
“Setting-up User Event Subscriptions” on page 61.
The table below cites:
• Reported Events – Events that require you to take action
• Corrective Actions – The action you should take in response to the event
A list of event categories is shown below.
• Battery (page 277)
• Blowers (page 278)
• Cache (page 279)
• Controller (page 279)
• Disk Array (page 279)
• Drive Interface Controller
(page 280)
• Enclosure (page 280)
• Event Log (page 280)
• Host Interface Controller
(page 280)
• Logical Drive (page 281)
• Media Patrol (page 282)
• Online Capacity Expansion
(page 283)
• PDM (page 283)
• Physical Disk (page 284)
• PSU (Power Supply Units)
(page 285)
• RAID Level Migration (page 286)
• Rebuild (page 286)
• Redundancy Check (page 287)
• Resource (page 288)
• Spare Check (page 288)
• Spare Drives (page 288)
• SMART (page 288)
• Synchronization (page 288)
• System (VessRAID) (page 289)
• Transition (page 289)
• Watermark (page 289)
Reported Event Corrective Action
Battery
Battery temperature is
above the threshold
The battery is too hot. Verify proper airflow around
the through the VessRAID. If airflow is OK, replace
the battery. See page 228.
Battery temperature is
normal
Normal.
Battery capacity is below
the threshold
Battery is drained. Run battery reconditioning. See
page 94 (WebPAM PROe) or page 143 (CLU).
Battery capacity is normal Normal.