VessRAID 1730s, 1740s, 1830s, 1840s Product Manual Version 1.
VessRAID 1000s Series Product Manual Copyright © 2009 Promise Technology, Inc. All Rights Reserved. Copyright by Promise Technology, Inc. (Promise Technology). No part of this manual may be reproduced or transmitted in any form without the expressed, written permission of Promise Technology. Trademarks Promise, and the Promise logo are registered in U.S. Patent and Trademark Office. All other product names mentioned herein may be trademarks or registered trademarks of their respective companies.
Contents Chapter 1: Introduction to VessRAID . . . . . . . . . . . . . . . . . . . . . . . . . .1 About This Manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 VessRAID Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2 Architectural Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 Features and Benefits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 Highlights . . . . . . . . . . . .
VessRAID 1000s Series Product Manual Chapter 2: VessRAID Installation, cont. Connecting the Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21 Front Panel LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21 Controller LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22 Disk Drive LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22 LCD Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Contents Chapter 4: Management with WebPAM PROe,cont. Working with the Storage Network . . . . . . . . . . . . . . . . . . . . . . . . .49 Viewing Other Subsytems . . . . . . . . . . . . . . . . . . . . . . . . . . . . .49 Updating the List of Subsystems . . . . . . . . . . . . . . . . . . . . . . .49 Logging into a Subsystem . . . . . . . . . . . . . . . . . . . . . . . . . . . . .49 Hiding the Other Subsystems . . . . . . . . . . . . . . . . . . . . . . . . . .49 Working with Subsystems . . . . . . . . .
VessRAID 1000s Series Product Manual Chapter 4: Management with WebPAM PROe,cont. Managing the Network Connection . . . . . . . . . . . . . . . . . . . . . . . . .65 Making Management Port Settings . . . . . . . . . . . . . . . . . . . . . .65 Managing SAS Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .66 Viewing SAS Port Information . . . . . . . . . . . . . . . . . . . . . . . . . .66 Making SAS Port Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Contents Chapter 4: Management with WebPAM PROe,cont. Managing Enclosures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .90 Viewing the Enclosure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .90 Locating an Enclosure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .90 Viewing Enclosure Topology . . . . . . . . . . . . . . . . . . . . . . . . . . .91 Viewing Enclosure Information . . . . . . . . . . . . . . . . . . . . . . . . .91 Making Enclosure Settings .
VessRAID 1000s Series Product Manual Chapter 4: Management with WebPAM PROe,cont. Managing Disk Arrays, cont. Running Media Patrol on a Disk Array . . . . . . . . . . . . . . . . . .115 Running PDM on a Disk Array . . . . . . . . . . . . . . . . . . . . . . . .116 Transitioning a Disk Array . . . . . . . . . . . . . . . . . . . . . . . . . . . .116 Preparing a Disk Array for Transport . . . . . . . . . . . . . . . . . . .117 Managing Logical Drives . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Contents Chapter 5: Management with the CLU, cont. Managing the Controller . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .137 Viewing Controller Information . . . . . . . . . . . . . . . . . . . . . . . .137 Clearing an Orphan Watermark . . . . . . . . . . . . . . . . . . . . . . .137 Making Controller Settings . . . . . . . . . . . . . . . . . . . . . . . . . . .137 Locating the Controller . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .138 Managing the Enclosure . . . . . . . .
VessRAID 1000s Series Product Manual Chapter 5: Management with the CLU, cont. Managing Disk Arrays, cont. Running PDM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .156 Running Transition on a Disk Array . . . . . . . . . . . . . . . . . . . .156 Locating a Disk Array . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .156 Creating a Logical Drive . . . . . . . . . . . . . . . . . . . . . . . . . . . . .157 Deleting a Logical Drive . . . . . . . . . . . . . . . . . . . .
Contents Chapter 5: Management with the CLU, cont. Working with LUN Mapping . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .172 Viewing a List of Initiators . . . . . . . . . . . . . . . . . . . . . . . . . . . .172 Enabling LUN Mapping . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .172 Creating an Initiator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .172 Mapping a LUN to an Initiator . . . . . . . . . . . . . . . . . . . . . . . . .173 Deleting an Initiator . .
VessRAID 1000s Series Product Manual Chapter 6: Management with the LCD Panel . . . . . . . . . . . . . . . . . .195 Using the LCD Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .195 Perusing the Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .196 Making Mode Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .196 Simple Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .196 Advanced Mode . . . . . . . . .
Contents Chapter 7: Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .219 Updating the Firmware in WebPAM PROe . . . . . . . . . . . . . . . . . .219 Downloading the Firmware Image File . . . . . . . . . . . . . . . . . .219 Updating Firmware from TFTP Server . . . . . . . . . . . . . . . . . .219 Updating Firmware from your PC . . . . . . . . . . . . . . . . . . . . . .220 Restarting the Subsystem . . . . . . . . . . . . . . . . . . . . . . . . . . . .
VessRAID 1000s Series Product Manual Chapter 8: Technology Background, cont. Choosing Stripe Size . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .247 Choosing Sector Size . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .247 2 TB Limitation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .248 Cache Policy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .248 Read Cache Policy . . . . . . . . . . . . . . . . . . . . .
Contents Chapter 9: Troubleshooting, cont. LCD Panel Reports a Problem . . . . . . . . . . . . . . . . . . . . . . . . . . .275 Viewing a Report from OPAS . . . . . . . . . . . . . . . . . . . . . . . . . . . .275 Event Notification Response . . . . . . . . . . . . . . . . . . . . . . . . . . . . .277 Critical & Offline Disk Arrays . . . . . . . . . . . . . . . . . . . . . . . . . . . . .290 When a Physical Drive Fails . . . . . . . . . . . . . . . . . . . . . . . . . .290 With a Hot Spare Drive . . . . .
VessRAID 1000s Series Product Manual xvi
Chapter 1: Introduction to VessRAID This chapter covers the following topics: • About This Manual (below) • VessRAID Overview (page 2) • Architectural Description (page 3) • Features and Benefits (page 3) • Specifications (page 6) About This Manual This Product Manual describes how to setup, use, and maintain the VessRAID 1700s and 1800s Series external disk array subsystems.
VessRAID 1000s Series Product Manual VessRAID Overview VessRAID provides data storage solutions for applications where high performance and data protection are required. The failure of any single drive will not affect data integrity or accessibility of the data in a RAID protected logical drive. Figure 1. VessRAID 1730s front view Drive Carrier LEDs Drive Carriers Power and Status LEDs A defective drive may be replaced without interruption of data availability to the host computer.
Chapter 1: Introduction to VessRAID Architectural Description The VessRAID 1700s and 1800s Series are Serial Attached SCSI (SAS) subsystems suitable for Direct Attached Storage (DAS) and Expanded Storage. The VessRAID subsystems support: • 3.0 Gb/s SATA disk drives • 3.0 Gb/s SAS disk drives All VessRAID enclosures include a mid-plane, RAID controller, power supply unit, and enclosure processor all in one cable-less chassis design.
VessRAID 1000s Series Product Manual • Three years complete system limited warranty includes 24 x 7 email and phone support with highly experienced technical support technicians and an advanced replacements program. • Support for the latest RAID technology—RAID 6—Protection from a catastrophic double-drive failure. • Resilient data protection features such as Predictive Data Migration™ and PerfectRAID™ provide rock solid data protection.
Chapter 1: Introduction to VessRAID • Maximum LUNs per array: 32 logical drives (LUNs). Supports LUN carving by allowing an array to be divided into multiple logical drives. Supports outof-order logical drive deletion and re-creation. • LUN Masking and Mapping: Supports multiple hosts. • Disk Data Formats: Supports Disk Data Format (DDF) for industry-wide standardization and drive roaming between VTrak systems.
VessRAID 1000s Series Product Manual Specifications Power Supply 1840s: 450W, Dual hot-swappable and redundant, 100-240 VAC auto-ranging, 50-60 Hz, with PFC 1830s: 350W, Dual hot-swappable and redundant, 100-240 VAC auto-ranging, 50-60 Hz, with PFC 1740s: 450W, Single, 100-240 VAC auto-ranging, 50-60 Hz, with PFC and 80PLUS certification 1730s: 350W, Single, 100-240 VAC auto-ranging, 50-60 Hz, with PFC and 80PLUS certification Current (maximum) 1840s: 8 A @ 100 VAC or 4 A @ 240 VAC current rating with two
Chapter 1: Introduction to VessRAID Dimensions (H x W x D) 1840s: 13 x 45 x 46 cm (5.1 x 17.7 x 18.1 in) 1830s: 8.8 x 45 x 46 cm (3.5 x 17.7 x 18.1 in) 1740s: 13 x 45 x 46 cm (5.1 x 17.7 x 18.1 in) 1730s: 8.8 x 45 x 46 cm (3.5 x 17.7 x 18.1 in) Net Weight 1840s: 16.0 kg (35.3 lb) without drives, 24.0 kg (52.9 lb) with 16 drives* 1830s: 13.0 kg (28.7 lb) without drives, 17.0 kg (37.5 lb) with 12 drives* 1740s: 14.0 kg (30.1 lb) without drives, 22.0 kg (48.5 lb) with 16 drives* 1730s: 11.0 kg (25.
VessRAID 1000s Series Product Manual CE Statement Warning: This is a class B product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures. FCC Statement This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Chapter 2: VessRAID Installation This chapter covers the following topics: • Unpacking the VessRAID (below) • Installing the LCD Panel (Optional) (page 11) • Mounting VessRAID in a Rack (page 13) • Installing Disk Drives (page 15) • Making Data and Management Connections (page 18) • Setting Up Serial Cable Connections (page 20) • Connecting the Power (page 21) Unpacking the VessRAID The VessRAID box contains the following items: • VessRAID Unit • Quick Start Guide printed • RJ11-to-DB9 se
VessRAID 1000s Series Product Manual VessRAID Models and Descriptions 1800s Model Drive Slots Power Supplies 1700s Model Drive Slots Power Supplies 1840s 16 2 1740s 16 1 1830s 12 2 1730s 12 1 Figure 1. VessRAID 1730s and 1830s front view Drive Carrier LEDs Drive Carriers Power and Status LEDs A defective drive may be replaced without interruption of data availability to the host computer.
Chapter 2: VessRAID Installation Figure 3. VessRAID 1730s rear view RAID Controller Power Supply For a description of the RAID Controller LEDs, see page 22. Installing the LCD Panel (Optional) Cautions • The LCD panel is NOT a hot-swap device. Be sure the VessRAID is powered down before you connect or disconnect the LCD panel. • You must install the LCD panel before you mount the VessRAID subsystem in a rack. The LCD panel mounts to the left ear of the VessRAID enclosure. 1.
VessRAID 1000s Series Product Manual 2. Insert the two screws that you removed in step 1 through the holes in the left bracket and into the threaded holes in the LCD panel, as shown in Figure 5. Tighten the screws to secure the LCD panel to the bracket. Figure 5. Attach the LCD panel to the VessRAID enclosure The LCD screen activates when the VessRAID boots. See “Connecting the Power” on page 21.
Chapter 2: VessRAID Installation Mounting VessRAID in a Rack The VessRAID subsystem installs to the rack using the optional mounting rails. You can also use your existing rails. Figure 6. VessRAID mounted in a rack with the optional rails Vertical Rack Post VessRAID subsystem Mounting rails mount outside the rack post Handles mount outside the rack post Cautions • At least two persons are required to safely lift, place, and attach the VessRAID subsystem into a rack system.
VessRAID 1000s Series Product Manual 3. Attach the mounting rail assemblies to the outside of the rack posts, using the attaching screws from your rack system. Be sure the support is on the bottom facing inward. 4. Square the rail assemblies in the rack. 5. Tighten the adjustment screws and the attaching screws. 6. Place the VessRAID subsystem onto the rails. 7. Secure the VessRAID subsystem to the rack through each handle, using the attaching screws from your rack system. Figure 7.
Chapter 2: VessRAID Installation Installing Disk Drives You can populate the VessRAID with SAS or SATA hard disk drives. For optimal performance, install physical drives of the same model and capacity. The drives’ matched performance allows the logical drive to function better as a single drive. The table below shows the number of drives required for each RAID level.
VessRAID 1000s Series Product Manual Figure 9. VessRAID 1730s and 1830s drive slot numbering 1 2 5 9 3 6 4 8 7 10 11 12 Install all of the drive carriers into the VessRAID enclosure to ensure proper airflow, even if you do not populate all the carriers with disk drives. Installing Your Disk Drives 1. Remove a disk drive carrier. 2. Carefully lay the disk drive into the drive carrier at the front, so that the screw holes on the sides line up. 3.
Chapter 2: VessRAID Installation Figure 10.Disk drive mounted in a drive carrier Disk drive mounting screw mounting screw This completes disk drive installation. Caution VessRAID supports disk drive hot-swapping. To avoid hand contact with an electrical hazard, do not remove more than one drive carrier a time.
VessRAID 1000s Series Product Manual Making Data and Management Connections You can configure your VessRAID for: • Direct Attached Storage (DAS) • DAS plus JBOD Expansion Note VessRAID does not support cascading of multiple RAID subsystems. Cascading is planned for a future release. Configuring a Data Path To establish the data path: 1. Connect the SAS HBA card in the Host PC to the SAS IN ports (with a circle icon) on the VessRAID controller. See Figure 11. 2.
Chapter 2: VessRAID Installation Figure 11. Data and management connections SAS HBA cards Host PCs or Servers Network Switch SAS Expansion port Diamond icon SAS IN ports Circle icon VessRAID SAS OUT port Diamond icon SAS IN port Circle icon VessJBOD SAS IN port Circle icon VessJBOD Caution Make data connections carefully. If you accidently switch a SAS IN connection with a SAS OUT, the RAID system cannot function. This completes data and management connections.
VessRAID 1000s Series Product Manual Setting Up Serial Cable Connections Serial communication enables the Command Line Interface (CLI) and Command Line Utility (CLU) on your PC to monitor and control the VessRAID. The VessRAID package includes a RJ11-to-DB9 serial data cable. Figure 12. A serial connector is located on the controller RJ11 Serial Connector To set up a serial cable connection: 1. Attach the RJ11 end of the serial data cable to the RJ11 serial connector on the controller. 2.
Chapter 2: VessRAID Installation Connecting the Power Plug-in the power cord on the power supply on the back of the VessRAID enclosure and switch on the power supply. If you have a redundant power supply, plug-in both power supplies and turn on both power supplies. When the power is switched on, the LEDs and LCD screen light up.
VessRAID 1000s Series Product Manual Controller LEDs When boot-up is finished and the VessRAID subsystem is functioning normally: • Battery, and Controller status LEDs display green continuously. • Management port activity LEDs display green or flash depending on your network connection. Figure 14.VessRAID Controller LEDs Fan 2 Fan 1 Battery Dirty JBOD Expansion Port USB 2 Cache Controller SAS IN Ports Status USB 1 Fan 2 Fan 1 Disk Drive LEDs There are two LEDs on each Drive Carrier.
Chapter 2: VessRAID Installation LCD Panel The LCD panel activates approximately 35 seconds after you switch on the VessRAID’s power supply. At first, the LCD screen displays System is Initializing. When the VessRAID is fully booted and running under normal conditions, the LCD screen shows the VessRAID model number and IP address, as shown in Figure 16. Figure 16.
VessRAID 1000s Series Product Manual 24
Chapter 3: VessRAID Setup This chapter covers the following topics: • Setting up the Serial Connection (below) • Choosing DHCP or a Static IP Address (page 26) • Setting up with the CLI (page 27) • Setting up with the CLU (page 28) • Setting up with the LCD (page 30) • Creating Disk Arrays with WebPAM PROe (page 32) Setting up the Serial Connection VessRAID has a Command Line Interface (CLI) to manage all of its functions, including customization.
VessRAID 1000s Series Product Manual Choosing DHCP or a Static IP Address When you setup your VessRAID, you have the option of: • Enabling DHCP and letting your DHCP server assign the IP address to the VessRAID’s management port. • Specifying a static IP address for the VessRAID’s management port. If you choose to enable DHCP, have your Network Administrator dedicate an IP address for the VessRAID, linked to the VessRAID’s MAC address.
Chapter 3: VessRAID Setup Setting up with the CLI 1. Type the following string to set the system date and time, then press Enter. administrator@cli> date -a mod -d 2009/01/25 -t 14:50:05 In the above example, the date and time are included as examples only. Your values will be different. Use yyyyy/mm/dd for the date and a 24-hour clock for the time. 2. Type the following string to set the Management Port IP address and other settings, then press Enter.
VessRAID 1000s Series Product Manual Setting up with the CLU 1. At the administrator@cli> prompt, type menu and press Enter. The CLU main menu appears. Figure 1. CLU main menu 2. With Quick Setup highlighted, press Enter. The first Quick Setup screen enables you to make Date and Time settings. Setting system date and time 1. Press the arrow keys to highlight System Date. 2. Press the backspace key to erase the current date. 3. Type the new date. 4.
Chapter 3: VessRAID Setup 3. Type the new IP Address. 4. Follow the same procedure to specify the Subnet Mask, Gateway IP Address and DNS Server IP Address. If you do not have a DNS server, skip the DNS Server IP address. 5. Press Ctrl-A to save your settings. Making Automatic IP Settings To make Management Port settings automatically: 1. Press the arrow keys to highlight DHCP. 2. Press the spacebar to toggle to Enable. 3. Press Ctrl-A to save these settings.
VessRAID 1000s Series Product Manual Setting up with the LCD The LCD Panel displays the current IP address during normal operation. If you did not install the LCD Panel, see “Installing the LCD Panel (Optional)” on page 11. The LCD does not have a date and time function. Figure 2. LCD Panel default view Making Manual IP Settings To make Management Port settings manually: 1. Press the 2. Press the or button until the display says Management Port. button and the display says Link Status Up.
Chapter 3: VessRAID Setup 7. Make the needed changes the same as in step 5. After you have set the last (extreme right) digit, press the button. The display says Save Network Setting? 8. Press the button to confirm. The display shows the new IP address you set. Making Automatic IP Settings To make Management Port settings automatically: 1. Press the 2. Press the or button until the display says Management Port. button and the display says Link Status Up.
VessRAID 1000s Series Product Manual Creating Disk Arrays with WebPAM PROe Note You can also use the CLU or the LCD panel to create disk arrays and logical drives. See page 148 or page 206 for more information. Setting up disk arrays with WebPAM PROe consists of the following actions: • Logging into WebPAM PROe (below) • Choosing a Language (page 34) • Creating a Disk Array (page 34) • Logging out of WebPAM PROe (page 38) Logging into WebPAM PROe 1. Launch your Browser. 2.
Chapter 3: VessRAID Setup 3. When the log-in screen (Figure 2) appears: • Type administrator in the User Name field. • Type password in the Password field. • Click the Login button. The User Name and Password are case sensitive. Figure 3. WebPAM PROe log-in screen After sign-in, the WebPAM PROe opening screen appears. If there are any unconfigured physical drives in the enclosure, an Array Configuration menu will also appear (see page 35).
VessRAID 1000s Series Product Manual Choosing a Language WebPAM PROe displays in English, German, French, Italian, Spanish, Russian, Japanese, Chinese Traditional, Chinese Simple, and Korean. 1. Click Language on the WebPAM PROe banner. The language list appears in the Header. 2. Click the language you prefer. The WebPAM PROe user interface displays in the selected language. Figure 4.
Chapter 3: VessRAID Setup Figure 5.
VessRAID 1000s Series Product Manual Express When you choose the Express option, a set of characteristics and options appears on the screen. 1. 2.
Chapter 3: VessRAID Setup Advanced Note For an explanation of the parameters under the Advanced option, see “Chapter 8: Technology Background” on page 233. Step 1 – Disk Array Creation 1. 2. 3. Enter a name for the disk array in the field provided. Check the boxes to enable the following features. • Media Patrol – A routine maintenance procedure that checks the magnetic media on each disk drive. Media Patrol is concerned with the condition of the media itself, not the data recorded on the media.
VessRAID 1000s Series Product Manual 5. Specify a Stripe size from the dropdown menu. 64, 128, 256, 512 KB, and 1 MB are available. 64 KB is the default. 6. Specify a Sector size from the dropdown menu. 512 Bytes, 1, 2, and 4 KB are available. 512 Bytes is the default. 7. Choose a Read Cache policy: Read Cache, Read Ahead Cache, and No Cache are available. Read Ahead is the default. 8. Choose a Write Cache policy: Write Back and Write Through are available. Write Back is the default. 9.
Chapter 3: VessRAID Setup Using WebPAM PROe over the Internet The above instructions cover connections between VessRAID and your company network. It is also possible to connect to a VessRAID from the Internet. Your MIS Administrator can tell you how to access your network from outside the firewall. Once you are logged onto the network, you can access the VessRAID using its IP address.
VessRAID 1000s Series Product Manual 40
Chapter 4: Management with WebPAM PROe This chapter covers the following topics: • Logging into WebPAM PROe (page 42) • Perusing the Interface (page 44) • Working with the Storage Network (page 49) • Working with Subsystems (page 50) • Managing Users (page 60) • Managing the Network Connection (page 65) • Managing SAS Connections (page 66) • Managing Storage Services (page 68) • Managing Software Services (page 71) • Exporting the User Database (page 78) • Importing a User Database (pag
VessRAID 1000s Series Product Manual Logging into WebPAM PROe 1. Launch your Browser. 2. In the Browser address field, type the IP address of the VessRAID subsystem. See “Setting up the Serial Connection” on page 25. Note that the IP address shown below is only an example. The IP address you type into your browser will be different. Regular Connection • WebPAM PROe uses an HTTP connection. . . . . . . . . . . . . . . .http:// • Enter the VessRAID’s IP address . . . . . . . . . . . . . . . 192.168.
Chapter 4: Management with WebPAM PROe Figure 1. WebPAM PROe log-in screen After sign-in, the WebPAM PROe opening screen appears. If there are any unconfigured physical drives in the enclosure, an Array Configuration menu will also appear (see page 31). Note Make a Bookmark (Netscape Navigator) or set a Favorite (Internet Explorer) of the Login Screen so you can access it easily next time.
VessRAID 1000s Series Product Manual Figure 2. Clicking “Language” on the WebPAM PROe banner Perusing the Interface WebPAM PROe is browser-based RAID management software with a graphic user interface. Figure 3.
Chapter 4: Management with WebPAM PROe There are four major parts to the graphic user interface: • Header (see below) • Tree (see page 46) • Management View (see page 47) • Event Frame (see page 47) Using the Header The Header contains the following items: • Language – To change languages, see “Selecting a Language” on page 43. • View – To view the Event Frame, see “Viewing the Event Frame” on page 47.
VessRAID 1000s Series Product Manual Using Tree View Tree View enables you to navigate around all components of the Subsystem, including SAS management, network and service management, RAID controller, enclosure, physical drives, disk arrays, logical drives, and spare drives. The figure below shows the components of Tree View. Figure 4.
Chapter 4: Management with WebPAM PROe Using Management View Management View provides the actual user interface with the VessRAID, including creation, maintenance, deletion, and monitoring of disk arrays and logical drives. Function Tabs control specific actions and processes. This window changes depending on which item you choose in Tree View and which tab you choose in Management View itself. Click the Help button in Management View to access online help for the function that is currently displayed.
VessRAID 1000s Series Product Manual Click the link a second time to change to flip the triangle and reverse the sort sequence. Logging out of WebPAM PROe There are two ways to log out of WebPAM PROe: • Close your browser window • Click Logout on the WebPAM PROe banner Figure 5. Clicking “Logout” on the WebPAM PROe banner Clicking Logout brings you back to the Login Screen. See page 43. After logging out, you must enter your user name and password in order to log in again.
Chapter 4: Management with WebPAM PROe Working with the Storage Network When you log into WebPAM PROe, you access a specific VessRAID subsystem. See “Logging into WebPAM PROe” on page 42. The Storage Network feature enables you to access all of the VessRAID subsytems with a Management Port connection to your network. Each VessRAID subsystem is identified by its Management Port IP address.
VessRAID 1000s Series Product Manual Working with Subsystems A VessRAID subsystem is identified by its Management Port IP address.
Chapter 4: Management with WebPAM PROe Setting an Alias for the Subsystem An alias is optional. To set an alias for this subsystem: 1. In Tree View, click the Subsystem icon. 2. In Management View, click the Settings tab. 3. Enter a name into the Alias field. Maximum of 48 characters. Use letters, numbers, space between words, and underscore. 4. Click the Submit button. Setting Subsystem Date and Time To set a Date and Time for this subsystem: 1. In Tree View, click the Subsystem icon. 2.
VessRAID 1000s Series Product Manual 3. • Time – Time and date of the occurrence • Description – A brief description of the event Click the link at the top of the column by which you want to sort the events. After you click the item, a triangle icon appears. • If the triangle points upward, the column is sorted low-to-high or old-tonew. • If the triangle points downward, the column is sorted high-to-low or newto-old.
Chapter 4: Management with WebPAM PROe 3. • Item Number – A consecutive decimal number assigned to a specific event • Device – Battery, controller, logical drive, physical drive, port, etc. • Event ID – The hexadecimal number that identifies the specific type of event • Severity – Information, Warning, Minor, Major, Critical, and Fatal. The severity level is user-specified. See “Setting-up User Event Subscriptions” on page 61.
VessRAID 1000s Series Product Manual Viewing Current Background Activities To view the current background activities: 1. 2. In Tree View, click the Subsystem icon. In Management View, click the Background Activities tab.
Chapter 4: Management with WebPAM PROe 5. 6. • Reassigned Block Threshold – 1 to 512 blocks • Error Block Threshold – 1 to 1024 blocks Check to enable or uncheck to disable the following functions: • Media Patrol – Checks the magnetic media on physical drives • Auto Rebuild – If there is a spare drive of adequate capacity, a critical disk array will begin to rebuild automatically.
VessRAID 1000s Series Product Manual Running PDM Predictive Data Migration (PDM) migrates data from the suspect physical drive to a spare disk drive, similar to Rebuilding. But unlike Rebuilding, PDM acts before the disk drive fails and your Logical Drive goes Critical. You an also run PDM on a specific disk array, see “Running PDM on a Disk Array” on page 116. Also see “Predictive Data Migration (PDM)” on page 260. To run PDM: 1. In Tree View, click the Subsystem 2.
Chapter 4: Management with WebPAM PROe 5. Select a Recurrence Pattern. • Daily – Enter the number of days between events. • Weekly – Enter the number of weeks between events and choose which days of the week. • Monthly – Choose a calendar day of the month (1 – 31). If you choose a higher number than there are days in the current month, the actual start date will occur at the beginning of the following month.
VessRAID 1000s Series Product Manual Viewing Lock Status The lock prevents other sessions (including by the same user) from making a configuration change to the controller until the lock expires or a forced unlock is done. To view the lock status for this subsystem: 1. Click the Subsystem 2. Click the Lock tab in Management View. icon Tree View. The following information is displayed: • Lock Status – The User who set (owns) the current lock.
Chapter 4: Management with WebPAM PROe 4. Enter a time interval between 1 and 1440 minutes (one day) that you want the lock to stay active. The renew time replaces the previous Expiration Time. 5. Click the Submit button. Releasing the Lock The lock prevents other sessions (including by the same user) from making a configuration change to the controller until the lock expires or a forced unlock is done. When the user who locked the controller logs out, the lock is automatically released.
VessRAID 1000s Series Product Manual Managing Users User Management includes all functions dealing with user accounts.
Chapter 4: Management with WebPAM PROe • Enter or change the email address. • From the Privilege dropdown menu, choose a new level. See “List of User Privileges” on page 63 7. Click the Submit button. The Administrator or Super User can change another user’s password. See “Changing Another User’s Password” on page 62 for more information. Making Your Own User Settings To change your own user settings: 1. Log into WebPAM PROe under your own user name. 2. Click the Subsystem 3.
VessRAID 1000s Series Product Manual 7. • Fatal – Non-Recoverable error or failure has occurred • None – Deactivates this event for notification purposes Click the Submit button. The user’s account must have an email address. See “Making User Settings” on page 60. For information about the email service, see “Making Email Settings” on page 71. To send a test message to the email address in the listed under General Info, click the Test Email button.
Chapter 4: Management with WebPAM PROe 8. Enter the new password in the Retype Password field. 9. Click the Submit button. Creating a User To create a user: 1. Log into WebPAM PROe as the Administrator or a Super User. 2. Click the Subsystem 3. Click the Administrative Tools icon in Tree View. icon. 4. Click the User Management 5. Click the Create tab in Management View. icon. 6. Enter a user name of 1 to 31 characters, no spaces, in the User Name field. 7.
VessRAID 1000s Series Product Manual Deleting a User There will always be at least one Super User account. You cannot delete the user account you used to log in. To delete a user: 1. Log into WebPAM PROe as the Administrator or a Super User. 2. Click the Subsystem 3. Click the Administrative Tools icon in Tree View. icon. 4. Click the User Management 5. Click the Delete tab in Management View. icon. 6. Check the box to the left of the user you want to delete. 7. Click the Submit button. 8.
Chapter 4: Management with WebPAM PROe Managing the Network Connection The network connection deals with the VessRAID’s Management Port. • Making Management Port Settings (below) Making Management Port Settings When you log into WebPAM PROe over your network, you use the VessRAID’s management port. Before you change settings, please see “Choosing DHCP or a Static IP Address” on page 26. To make changes to the Management Port settings: 1. Click the Subsystem icon in Tree View. 2.
VessRAID 1000s Series Product Manual Managing SAS Connections SAS connections deal with the VessRAID’s two host data ports. • Viewing SAS Port Information (page 66) • Making SAS Port Settings (page 66) • Viewing SAS Port Statistics (page 67) • Viewing SAS Initiators (page 67) Viewing SAS Port Information The SAS Controller has one SAS channel. The SAS channel has two ports.
Chapter 4: Management with WebPAM PROe The range is 1 to 8. 1 is the default. Signal strength correlates to cable length in meters. Example: If you have a 2 m SAS cable, set signal strength to 2. If performance is unsatisfactory (see “Viewing SAS Port Statistics” on page 67), try settings of 1 and 3, then use the best setting for your system. 6. Click the Submit button.
VessRAID 1000s Series Product Manual Managing Storage Services Storage services deal with initiators and LUN mapping. LUN masking is the process of applying a LUN Map so that each initiator can only access the LUNs specified for it.
Chapter 4: Management with WebPAM PROe 3. Click the Storage Services icon. 4. Click the Initiators tab in Management View. 5. From the Initiators tab dropdown menu, choose Delete Initiators. 6. Check the box to the left of the initiator you want to delete. 7. Click the Submit button. Viewing the LUN Map To view the current LUN Map: 1. Click the Subsystem icon in Tree View. 2. Click the Administrative Tools 3. Click the Storage Services 4. Click the LUN Map tab in Management View. icon.
VessRAID 1000s Series Product Manual You must enter different LUN numbers for each logical drive. 7. Click the Submit button. Editing a LUN Map To edit the LUN Map: 1. Click the Subsystem icon in Tree View. 2. Click the Administrative Tools icon. 3. Click the Storage Services 4. Click the LUN Map tab in Management View. icon. 5. From the LUN Mapping & Masking Information list, choose an initiator and click its link. Or enter the initiator's name in the Initiator Name field.
Chapter 4: Management with WebPAM PROe Managing Software Services Software Services include the following functions: • Making Email Settings (page 71) • Making SLP Settings (page 72) • Making Web Server Settings (page 73) • Making Telnet Settings (page 74) • Making SNMP Settings (page 74) • Making Netsend Settings (page 76) Making Email Settings The Email sends notification messages to users. See Setting-up User Event Subscriptions (page 61). To make Email service settings: 1.
VessRAID 1000s Series Product Manual Changing the Startup Setting 1. 2. Under Startup Type: • Click the Automatic option to start the service automatically during system startup. Recommended. • Click the Manual option to start the service manually (the service does not start during system startup). Click the Submit button. Stopping Email service To stop the Email service: 1. Click the Stop button. 2. Click OK in the confirmation box.
Chapter 4: Management with WebPAM PROe Making Web Server Settings The Web Server service connects your browser to the WebPAM PROe GUI on the VessRAID subsystem. To make Web Server settings: 1. Click the Subsystem icon in Tree View. 2. Click the Administrative Tools 3. Click the Web Server Setting link in Management View. 4. Enter the HTTP Port number. icon. 80 is the default. 5. Enter Session Time Out interval. This setting causes WebPAM PROe to time-out after a period of inactivity.
VessRAID 1000s Series Product Manual Making Telnet Settings VessRAID’s Telnet service enables you to access VessRAID’s Command Line Interface (CLI) through a network connection. To make Telnet settings: 1. Click the Subsystem 2. Click the Administrative Tools 3. Click the Telnet Setting link in Management View. 4. icon in Tree View. icon. Enter the Telnet Port number. 2300 is the default. 5. Enter the Maximum Number of Connections. 4 is the default. 6. Enter the Session Time Out interval.
Chapter 4: Management with WebPAM PROe To change the SNMP settings: 1. Click the Subsystem 2. Click the Administrative Tools 3. Click the SNMP Management link in Management View. 4. icon in Tree View. icon. Enter the SNMP Port number. 161 is the default. 5. Enter a System Name. There is no default name. 6. Enter a System Location. USA is the default. 7. 8. Enter a System Contact (the email address of the administrator or other individual). Enter the Read Community. Public is the default. 9.
VessRAID 1000s Series Product Manual 4. Click OK in the confirmation box. Changing the Startup Setting 1. 2. Under Startup Type: • Click the Automatic option to start the service automatically during system startup. Recommended. • Click the Manual option to start the service manually (the service does not start during system startup). Click the Submit button. Stopping SNMP service To stop the SNMP service: 1. Click the Stop button. 2. Click OK in the confirmation box.
Chapter 4: Management with WebPAM PROe 5. Click OK in the confirmation box. Deleting Netsend Recipients To delete a Netsend recipient: 1. Highlight the recipient you want to delete in the recipient list. 2. Click the Delete button to remove the recipient from the list. 3. Click the Submit button. 4. Click OK in the confirmation box. Changing the Startup Setting 1. 2. Under Startup Type: • Click the Automatic option to start the service automatically during system startup.
VessRAID 1000s Series Product Manual Exporting the User Database You can export the User Database file to share user information and settings among multiple VessRAID subsystems. The Export action saves a text file a designated folder the Host PC. From there, you can import the User Database file to other VessRAID subsystems. To export the User Database file: 1. Click the Subsystem icon in Tree View. 2. Click the Administrative Tools 3. Click the Export link in Management View. 4.
Chapter 4: Management with WebPAM PROe 5. 6. Under the Type dropdown list, choose User Database. Enter the name of the file to be imported. Or, click the Browse... button to search for the file. Look for a file called export. 7. 8. Click the Submit button. Click the Next button. If the imported file is a valid user database, a warning will appear to inform you that it will overwrite the previous settings. 9. In the Warning box, click the OK button.
VessRAID 1000s Series Product Manual The new configuration is applied to this VessRAID subsystem. Note The Decryption box is grayed out. Decryption is disabled for configuration scripts. Updating the Firmware See “Chapter 7: Maintenance” on page 219 for instructions.
Chapter 4: Management with WebPAM PROe Restoring Factory Defaults VessRAID includes a function to restore the default settings to its Firmware and Software settings. Caution The action of restoring default settings can disrupt your VessRAID functions. Use this feature only when necessary and only the settings that must reset to default in order to set them correctly. To access the Restore Defaults feature: 1. Click the Subsystem icon in Tree View. 2. Click the Administrative Tools icon.
VessRAID 1000s Series Product Manual Shutting Down the Subsystem You can only do part of this function in WebPAM PROe. Additional action is required, as described below. Important If you have a JBOD Expansion, always power off the RAID subsystem first. Then power off the JBOD subsystems. To shutdown the subsystem: 1. Click the Subsystem 2. Click the Administrative Tools 3. icon in Tree View. icon. Click the Shutdown link in Management View. A Shutdown or Restart tab will appear. 4.
Chapter 4: Management with WebPAM PROe Monitoring the Shutdown To monitor a shutdown, you must use the Command Line Interface (CLI) though a serial connection to the VessRAID. Turn off both power supply switches when the following this message appears: Shutdown complete. It is now safe to power off the subsystem.
VessRAID 1000s Series Product Manual Starting Up After Shutdown Important If you have a JBOD Expansion, always power on the JBOD subsystems first. Then power on the RAID subsystem. To start the RAID subsystem: 1. Manually turn on the power supply switches on the back of the subsystem. If the switches are ON but the subsystem is OFF, turn the switches off and on again. On subsystems with redundant power supplies, if the power switches do not respond, unplug the power cords and plug them back in.
Chapter 4: Management with WebPAM PROe Restarting the Subsystem Note If you have a JBOD Expansion, you are not required to restart the JBOD subsystems when you restart the RAID subsystem. You can only do part of this function in WebPAM PROe. Additional action is required, as described below. To restart the subsystem 1. Click the Subsystem icon in Tree View. 2. Click the Administrative Tools 3. Click the Shutdown link in Management View. icon. A Shutdown or Restart tab will appear. 4.
VessRAID 1000s Series Product Manual Managing the Controller The RAID controller is the heart of the VessRAID subsystem. Controller management includes the following functions: • Viewing Controller Information (page 86) • Viewing Controller Information (page 86) • Viewing Controller Statistics (page 87) • Making Controller Settings (page 87) • Clearing an Orphan Watermark (page 88) Viewing the Controller To view information about the controller: 1. Click the Subsystem icon in Tree View. 2.
Chapter 4: Management with WebPAM PROe • Write Back Cache Flush Interval • Enclosure Polling Interval See “Making Controller Settings” on page 87. Upgradable items You can upgrade the following items: • Boot loader Version • Firmware Version number • Software Version number • Memory Size See “Chapter 7: Maintenance” on page 219. Viewing Controller Statistics To view controller statistics: 1. Click the Subsystem icon in Tree View. 2. Click the Controllers icon. 3.
VessRAID 1000s Series Product Manual 5. Make the following settings as needed: • Enter a name into the Alias field. Maximum of 48 characters. Use letters, numbers, space between words, and underscore. An alias is optional. • Check the SMART Log box to enable the Self-Monitoring, Analysis, and Reporting System (SMART). • Enter a polling interval (1 to 1440 minutes) in SMART Polling Interval field. • Check the Coercion Enabled box to enable disk drive capacity coercion.
Chapter 4: Management with WebPAM PROe To clear an Orphan Watermark: 1. Click the Subsystem icon in Tree View. 2. Click the Controllers icon. 3. Click the Controller 4. Click the Clear tab in Management View. icon. 5. Click the Submit button. The changes take effect immediately.
VessRAID 1000s Series Product Manual Managing Enclosures On VessRAID, enclosures include the main VessRAID subsystem or Head Unit as well as VessJBOD enclosures that are connected through expansion.
Chapter 4: Management with WebPAM PROe Figure 6. Disk Status LED Disk Status Figure 7. VessRAID enclosure LEDs Dirty Cache USB 1 Controller Status USB 2 Fan 2 Fan 1 Battery Viewing Enclosure Topology To view Enclosure Topology: 1. Click the Subsystem icon in Tree View. 2. Click the Enclosures icon. 3. Click the Topology tab in Management View.
VessRAID 1000s Series Product Manual 2. 3. Click the Enclosures Click the Enclosure icon. icon. Enclosure information appears the Information tab in Management View. You can monitor power supplies, fans, enclosure temperatures and voltages, and the battery. Adjustable items You can set or adjust the following items: • Enclosure Warning and Critical temperature thresholds • Controller Warning and Critical temperature thresholds See “Making Enclosure Settings” on page 92.
Chapter 4: Management with WebPAM PROe 3. Click the Enclosure 4. Click the FRU VPD tab in Management View. icon. Use this information when communicating with Technical Support and when ordering replacement units. For contact information, see “Contacting Technical Support” on page 305. Checking the Battery The Enclosure–Battery tab displays information about the cache backup battery (or batteries) in the VessRAID subsystem enclosure. To check the batteries: 1. Click the Subsystem icon in Tree View.
VessRAID 1000s Series Product Manual Reconditioning a Battery To recondition the battery: 1. Click the Subsystem icon in Tree View. 2. Click the Enclosures icon. 3. Click the Enclosure 4. Click the Battery tab in Management View. icon. 5. From the Battery tab dropdown menu, choose Recondition. 6. Click the Submit button. Reconditioning fully discharges, then fully recharges the battery.
Chapter 4: Management with WebPAM PROe 4. 5. In Management View, from the Buzzer tab dropdown menu, choose Settings. Check the Buzzer Enable box to enable the buzzer. Uncheck the Buzzer Enable box if you do not want the buzzer to sound. 6. Click the Submit button. Testing the Buzzer You must enable the buzzer before you can test it. To test buzzer function: 1. Click the Subsystem icon in Tree View. 2. Click the Enclosures icon. 3. Click the Enclosure 4. Click the Buzzer tab in Management View.
VessRAID 1000s Series Product Manual Managing Physical Drives Managing Physical Drives deals with the physical disk drives installed in the VessRAID subsystem enclosure, including the following functions: • Viewing a List of Physical Drives (page 96) • Identifying a Physical Drive (page 96) • Making Global Physical Drive Settings (page 97) • Viewing Physical Drive Information (page 97) • Viewing Physical Drive Statistics (page 98) • Making Physical Drive Settings (page 98) • Clearing Stale and
Chapter 4: Management with WebPAM PROe Making Global Physical Drive Settings Global settings apply to all of the physical disk drives installed in the VessRAID subsystem enclosure. To make global physical drive settings: 1. Click the Subsystem icon in Tree View. 2. Click the Enclosures 3. Click the Enclosure 4. Click the Physical Drives icon. icon. icon. 5. Click the Global Settings tab in Management View. 6. Make the settings as needed.
VessRAID 1000s Series Product Manual • Operational Status – OK is normal. Can also show Rebuilding, Forced Online, Forced Offline, Transition Running, PDM Running, Media Patrol Running, Stale, PFA, Offline, or Dead. • Configuration Status – The array to which the drive is assigned or its spare designation, including Unconfigured, Stale, PFA, Global Spare, Dedicated Spare, Revertible Global Spare, Revertible Dedicated Spare.
Chapter 4: Management with WebPAM PROe 6. 7. Click the Settings tab in Management View. Type an alias into the Physical Drive Alias field. Maximum of 32 characters. Use letters, numbers, space between words, and underscore. An alias is optional. 8. Click the Submit button. Clearing Stale and PFA Conditions The Clear tab only appears when those conditions are present. • Stale – The physical drive contains obsolete disk array information.
VessRAID 1000s Series Product Manual Forcing a Physical Drive Offline or Online The Physical Drive–Force Offline/Online tab enables you to force an: • Online physical drive to go Offline • Offline physical drive to go Online The Force Offline/Online tab appears only for physical drives that are assigned to disk arrays. Caution Forcing a physical drive offline or online is likely to cause data loss. Back up your data before you proceed. Use these functions only when required.
Chapter 4: Management with WebPAM PROe 6. Click the physical drive you want to locate on the WebPAM PROe screen. The disk status LED for the physical drive blinks for one minute. Figure 8.
VessRAID 1000s Series Product Manual Managing UPS Units Uninterruptible Power Supply (UPS) Management includes the following functions: • Viewing a List of UPS Units (below) • Making UPS Settings (page 103) • Viewing UPS Information (page 104) Viewing a List of UPS Units To view a list of UPS units supporting the VessRAID: 1. Click the Subsystem 2. Click the UPS 3. icon in Tree View. icon. Click the Information tab in Management View.
Chapter 4: Management with WebPAM PROe Making UPS Settings These settings control how the VessRAID subsystem detects the UPS unit and responds to data reported by the UPS unit. To make UPS settings: 1. Click the Subsystem icon in Tree View. 2. Click the UPS 3. Click the Settings tab in Management View. 4. Perform the following actions as required: • • • • 5. icon. Verify the Current UPS Communication method: • USB – USB connection. • Unknown – No connection.
VessRAID 1000s Series Product Manual Notes 1. Detection Setting must be set to Auto. If a UPS is detected, the setting changes to Enable. 2. The maximum recommended Loading Ratio varies among models of UPS units. The general range is 60% to 80%. Viewing UPS Information To view information about a specific UPS unit: 1. Click the Subsystem 2. Click the UPS 3. Click the UPS1 4. icon in Tree View. icon. or UPS2 icon. Click the UPS tab in Management View.
Chapter 4: Management with WebPAM PROe Managing Disk Arrays Disk Array Management includes the following functions: • Viewing Disk Arrays (page 105) • Creating a Disk Array (page 105) • Deleting a Disk Array (page 110) • Viewing Disk Array Information (page 110) • Making Disk Array Settings (page 111) • Creating a Logical Drive (page 112) • Deleting a Logical Drive (page 113) • Migrating a Disk Array (page 113) • Rebuilding a Disk Array (page 114) • Running PDM on a Disk Array (page 116)
VessRAID 1000s Series Product Manual • Advanced – You directly specify all parameters for a new disk array. Makes one logical drive automatically. You can create additional logical drives at a later time, if additional configurable capacity is available. Does not make a hot spare drive. See “Creating a Disk Array – Advanced” on page 108. Creating a Disk Array – Automatic The Disk Array Automatic Creation option enables you to create a new disk array following a default set of parameters.
Chapter 4: Management with WebPAM PROe Creating a Disk Array – Express The Disk Array Express Creation option enables you to choose the parameters for a new disk array by specifying the characteristics you want. With this method, you can create multiple logical drives at the same time you create your disk array. However, all of the logical drives will be the same. If you prefer to specific the parameters directly, use the Advanced option to create your disk array.
VessRAID 1000s Series Product Manual The following parameters display: • Disk Arrays – The number of physical drives in the disk array, their slot numbers, configurable capacity, and the number of logical drives to be created • Logical Drives – The slot number of the logical drive(s), their RAID level, capacity, and stripe size • Spare Drives – The physical drive slot number of the dedicated hot spare assigned to this disk array (all RAID levels except RAID 0) If you have both Hard Disk Drives (HDD)
Chapter 4: Management with WebPAM PROe migration of data from the suspect drive (the disk drive with the bad sectors) to a spare disk drive. 3. From the Media Type dropdown menu, choose the physical drive type to use in the array. • HDD – Hard Disk Drives • SSD – Solid State Drives The drive type you selected appears in the list of Physical Drives. You cannot mix HDDs and SSDs in the same disk array. 4.
VessRAID 1000s Series Product Manual 11. When you have finished specifying logical drives, click the Next button. Step 3 – Summary The Summary lists the disk array and logical drive information you specified. To proceed with disk array and logical drive creation, click the Submit button. Note This function does not automatically create a hot spare drive. After the disk array is created, you can create a hot spare drive for it. For more information, see “Creating a Spare Drive” on page 125.
Chapter 4: Management with WebPAM PROe Disk Array Operational Status • OK – The normal state of a disk array. For RAID Levels other than RAID 0 (Striping), the disk array has full redundancy. • Synchronizing – When you first create a disk array, the disk array synchronizes. During that time, your data is available. However, access will be slower until synchronizing is done. • Critical/Degraded – This condition results from a physical drive failure. Your data is still available.
VessRAID 1000s Series Product Manual Creating a Logical Drive When you create a disk array, you automatically create one logical drive also. If the initial logical drive used less than the full capacity of the disk array, you can create additional logical drives from the same disk array. To create a logical drive: 1. Click the Subsystem icon in Tree View. 2. Click the Disk Arrays icon. 3. Click the Disk Array 4. Click the Create LD tab in Management View. 5.
Chapter 4: Management with WebPAM PROe 13. Click the Update button to enter the logical drive parameters. 14. Review the results. If there is remaining space the disk array, you can create another logical drive, following the steps above. Each logical drive can have a different set of parameters. 15. Click the Next button when you are done. A new window displays with the disk array information and the proposed logical drives with their parameters. 16. Click the Submit button create the logical drives.
VessRAID 1000s Series Product Manual For a list of Migration options and other important information, see “RAID Level Migration” on page 252. Notes • You can add physical drives to a RAID 50 or RAID 60 array but you cannot change the number of axles. • If you add an odd number of physical drives to a RAID 10 array, it will become a RAID 1E array by default. To Migrate an existing disk array: 1. Click the Subsystem icon in Tree View. 2. Click the Disk Arrays icon. 3. Click the Disk Array 4.
Chapter 4: Management with WebPAM PROe Rebuilding Automatically Normally, a disk array would rebuild itself using a hot disk drive, after going Critical. However, if the Auto Rebuild function is disabled or no spare drives are available, you must initiate the procedure. To enable Auto Rebuild, see “Making Background Activity Settings” on page 54. To create a spare drive, see “Creating a Spare Drive” on page 125. For more information, see “Hot Spare Drive(s)” on page 251.
VessRAID 1000s Series Product Manual To start Media Patrol: 1. Click the Subsystem icon in Tree View. 2. Click the Disk Arrays icon. 3. Click the Disk Array 4. From the dropdown menu the Background Activities tab, choose Start Media Patrol. 5. Click the Start button. icon. Running PDM on a Disk Array Predictive Data Migration (PDM) migrates data from the suspect physical drive to a spare physical drive, similar to Rebuilding.
Chapter 4: Management with WebPAM PROe To run Transition: 1. Click the Subsystem 2. From the dropdown menu on the Background Activities tab, choose Start Transition. icon in Tree View. 3. Choose an unconfigured physical drive from the list of available drives. 4. From the Target Physical Drive dropdown menu, choose an unconfigured physical drive. The available drives are either HDD or SSD, depending on the type of drives in the array. 5. Click the Submit button.
VessRAID 1000s Series Product Manual Managing Logical Drives Logical drives are made from disk arrays. In the Tree, you can see a graphic representation of the logical drives that belong to each array. You can see a summary of all logical drives in the subsystem under Logical Drive Summary.
Chapter 4: Management with WebPAM PROe may remain intact. You must determine the cause of the problem and correct it. “Critical & Offline Disk Arrays” on page 290 • Transport Ready – The result of a successful Prepare for Transport operation. You remove the physical drives of this logical drive and move them to another enclosure or to different drive slots in the same enclosure. After you relocate the physical drives, the logical drive status will show OK.
VessRAID 1000s Series Product Manual Viewing Logical Drive Statistics To view information for a single logical drive: 1. Click the Subsystem icon in Tree View. 2. Click the Disk Arrays icon. 3. Click the Disk Array 4. Click the Logical Drives 5. Click the Logical Drive 6. In Management View, from the dropdown menu on the Information tab, choose Statistics. icon. icon icon. Clearing Statistics To clear statistics, see “Clearing Statistics” on page 81.
Chapter 4: Management with WebPAM PROe because there may be residual data the logical drives left behind from earlier configurations. For this reason, Initialization is recommended for all new logical drives. Caution When you initialize a logical drive, all the data the logical drive will be lost. Backup any important data before you initialize a logical drive. Initialize a Logical Drive: 1. Click the Subsystem icon in Tree View. 2. Click the Logical Drive Summary 3. Click the icon.
VessRAID 1000s Series Product Manual 3. Click the icon of the logical drive you want to Initialize. You can also start Redundancy check from the Subsystem Background Activities tab icon 4. From the dropdown menu on the Background Activities tab, choose Redundancy Check. 5. To choose Auto Fix, check the box. This feature attempts to repair the problem when it finds an error. 6. To choose Pause On Error, check the box. This feature stops the process when it finds an error.
Chapter 4: Management with WebPAM PROe Table Definitions • Read Check Table – Contains a list of read errors for this logical drive. • Write Check Table – Contains a list of write errors for this logical drive. • Inconsistent Block Table – Contains a list of inconsistent blocks for this logical drive. Mirror data for RAID Levels 1, 1E, and 10 or Parity data for RAID Levels 5, 6, 50, and 60 identified by the Redundancy Check (a background function).
VessRAID 1000s Series Product Manual Managing Spare Drives When a physical drive in a disk array fails and a spare drive of adequate capacity is available, the disk array will begin to rebuild automatically using the spare drive. See “Critical & Offline Disk Arrays” on page 290.
Chapter 4: Management with WebPAM PROe 3. Click the Spare Drive icon. In Management View, the Enclosure Front View diagram appears with the location of the spare drive highlighted. Creating a Spare Drive Important • There must be an unconfigured physical drive available for selection as a spare drive. See “Viewing a List of Physical Drives” on page 96. • Be sure the unconfigured physical drive has adequate capacity to replace the largest drive in the disk array. To create a spare drive: 1.
VessRAID 1000s Series Product Manual 10. If you selected a Dedicated spare drive, in the Dedicated to Disk Arrays field, highlight disk arrays to which you want assign the spare drive from the Available list and press the >> button to move the array to the Selected list. You can also double-click arrays to move them. 11. Click the Update button. Your choices are displayed under New Hot Spare Drives. 12. If you agree with the proposed choices, click the Submit button.
Chapter 4: Management with WebPAM PROe 7. If you selected a Dedicated spare drive, in the Dedicated to Disk Arrays field, highlight the disk arrays to which you want assign the spare drive from the Available list and press the >> button to move them to the Selected list. You can also double-click array to move it. 8. Click the Submit button. Running Spare Check Spare Check verifies the operational status of your spare drives. You can also schedule a Spare Check. See “Scheduling an Activity” on page 56.
VessRAID 1000s Series Product Manual Working with the Logical Drive Summary The Logical Drive Summary displays a list of all logical drives in the VessRAID enclosure plus the expanded or cascaded enclosures. This list does not arrange the logical drives under the disk array to which they belong nor under the enclosure in which they are located.
Chapter 5: Management with the CLU This chapter covers the following topics: • Initial Connection (page 130) • Running Quick Setup (page 134) • Managing the Subsystem (page 135) • Managing the Controller (page 137) • Managing the Enclosure (page 140) • Managing Physical Drives (page 145) • Managing Disk Arrays (page 148) • Managing Spare Drives (page 159) • Managing Logical Drives (page 162) • Managing the Network Connection (page 165) • Managing SAS Connections (page 166) • Managing
VessRAID 1000s Series Product Manual Initial Connection Making an initial connection includes the following functions: • Making a Serial Connection (below) • Making a Telnet Connection (page 131) • Logging In (page 131) • Accessing Online Help (page 133) • Exiting the CLU (page 133) • Logging Out of the CLI (page 133) • Logging Back Into the CLI and CLU (page 133) Making a Serial Connection Before you begin, be sure the RJ11-to-DB9 serial data cable is connected between the Host PC and VessRA
Chapter 5: Management with the CLU Making a Telnet Connection A Telnet connection requires a network connection between the Host PC and VessRAID controller’s Management (Ethernet) port. Figure 2. Management port on the controller Management port To start the telnet program: 1. Go to the command line prompt (Windows) or click the terminal icon (Linux). 2. Type telnet 192.168.1.56 2300 and press Enter. The IP address above is only an example. Use your VessRAID's Management port IP address.
VessRAID 1000s Series Product Manual Figure 3. CLU main menu Quick Setup – A sequence of four steps to setup System Date & Time, Management Port, and RAID Configuration. Subsystem Management – View controller information, lock/unlock the controller, set date and time, and monitor the enclosure. Physical Drive Management – View disk drive assignments and parameters, change disk drive cache settings and command queuing, and locate a physical drive.
Chapter 5: Management with the CLU Background Activity – Settings for Media Patrol, Auto Rebuild, Rebuild, Migration, PDM, Transition, Synchronization, Initialization, Redundancy Check rate, and thresholds. Event Viewer – View the event logs. Additional Info and Management – Spare Drives, LUN Mapping, User management, Email, SLP, Web Server, Telnet, SNMP, and Netsend settings, firmware flash, clear statistics and restore factory default settings.
VessRAID 1000s Series Product Manual Running Quick Setup Quick Setup is discussed under “Setting up the Serial Connection” on page 25.
Chapter 5: Management with the CLU Managing the Subsystem Subsystem Management includes the following functions: • Setting an Alias for the Subsystem (page 135) • Running Media Patrol (page 135) • Locking or Unlocking the Subsystem (page 135) • Setting Subsystem Date and Time (page 136) Setting an Alias for the Subsystem An alias is optional. To set an Alias for this subsystem: 1. 2. From the Main Menu, highlight Subsystem Management and press Enter. Type and alias into the Alias field.
VessRAID 1000s Series Product Manual 4. Highlight Lock and press Enter. Resetting the Lock To reset the lock with a new time: 1. From the Main Menu, highlight Subsystem Management and press Enter. 2. Highlight Lock Management and press Enter. 3. In the Lock Time field, type a lock time in minutes. 1 to 1440 minutes (24 hours) 4. Highlight Renew and press Enter. Releasing the Lock 1. From the Main Menu, highlight Subsystem Management and press Enter. 2.
Chapter 5: Management with the CLU Managing the Controller Controller Management includes the following functions: • Viewing Controller Information (page 137) • Clearing an Orphan Watermark (page 137) • Making Controller Settings (page 137) • Locating the Controller (page 138) Viewing Controller Information Controller Management includes information, settings and statistics. To access Controller Management: 1. From the Main Menu, highlight Subsystem Management and press Enter. 2.
VessRAID 1000s Series Product Manual 3. Highlight the controller you want and press Enter. 4. Highlight Controller Settings and press Enter. 5. Make the following settings as required: • Type and alias into the Alias field. Maximum of 48 characters. Use letters, numbers, space between words and underscore. An alias is optional. • Highlight Coercion and press the spacebar to toggle between Enabled and Disabled.
Chapter 5: Management with the CLU Figure 4.
VessRAID 1000s Series Product Manual Managing the Enclosure Enclosure Management includes the following functions: • Viewing Enclosure Information (page 140) • Viewing Power Supply Status (page 140) • Locating a Power Supply (page 141) • Viewing Cooling Unit Status (page 141) • Viewing Voltage Sensor Status (page 141) • Viewing Temperature Sensor Status (page 141) • Setting Temperature Thresholds (page 142) • Checking the Batteries (page 142) • Reconditioning a Battery (page 143) • Locat
Chapter 5: Management with the CLU Locating a Power Supply To locate a power supply: 1. From the Main Menu, highlight Subsystem Management and press Enter. 2. Highlight Enclosure Management and press Enter. 3. Highlight Power Supplies and press Enter. 4. Highlight Locate Power Supply and press Enter. The LED on the selected power supply blinks for one minute. Viewing Cooling Unit Status To view the status of the blowers: 1. From the Main Menu, highlight Subsystem Management and press Enter. 2.
VessRAID 1000s Series Product Manual Setting Temperature Thresholds To change temperature thresholds: 1. From the Main Menu, highlight Subsystem Management and press Enter. 2. Highlight Enclosure Management and press Enter. 3. Highlight Enclosure Settings and press Enter. 4. Highlight the Temperature Warning threshold you want to change. 5. Press the backspace key to erase the current value. 6. Type a new interval value in degrees C. 7. Press Ctrl-A to save your settings.
Chapter 5: Management with the CLU controller before reconditioning is finished, the battery is charged to 100%, then reconditioning starts again. Reconditioning a Battery To recondition the subsystem battery: 1. From the Main Menu, highlight Subsystem Management and press Enter. 2. Highlight Enclosure Management and press Enter. 3. Highlight Batteries and press Enter. 4. Highlight the battery you want to recondition and press Enter. 5. Highlight Start Reconditioning and press Enter. 6.
VessRAID 1000s Series Product Manual Figure 6.
Chapter 5: Management with the CLU Managing Physical Drives Physical Drive Management includes the following functions: • Making Global Physical Drive Settings (page 145) • Setting an Alias (page 146) • Viewing Advanced Information (page 146) • Viewing Physical Drive Statistics (page 146) • Clearing Stale and PFA Conditions (page 146) • Forcing a Physical Drive Offline or Online (page 147) • Locating a Physical Drive (page 147) Making Global Physical Drive Settings All physical drive settings
VessRAID 1000s Series Product Manual Setting an Alias An alias is optional. To set an Alias for a physical drive: 1. From the Main Menu, highlight Physical Drive Management and press Enter. 2. Highlight the physical drive of your choice and press Enter. 3. Type an alias into the Alias field. Maximum of 32 characters. Use letters, numbers, space between words and underscore. 4. Press Ctrl-A to save your settings.
Chapter 5: Management with the CLU After you clear a PFA error, watch for another PFA error to appear. If it does, replace the physical drive. Forcing a Physical Drive Offline or Online This function enables you to force an: • Online physical drive to go Offline • Offline physical drive to go Online The Force Offline/Online function appears only for physical drives that are assigned to disk arrays. Caution Forcing a physical drive offline or online is likely to cause data loss.
VessRAID 1000s Series Product Manual Managing Disk Arrays Disk Array Management includes the following functions: • Creating a Disk Array (page 148) • Deleting a Disk Array (page 152) • Viewing Disk Array Information (page 152) • Setting an Alias for a Disk Array (page 153) • Enabling Media Patrol on a Disk Array (page 154) • Enabling PDM on a Disk Array (page 154) • Preparing the Disk Array for Transport (page 154) • Rebuilding a Disk Array (page 154) • Migrating a Disk Array (page 155)
Chapter 5: Management with the CLU Creating a Disk Array – Automatic To create a disk array using the Automatic feature: 1. From the Main Menu, highlight Disk Array Management and press Enter. 2. Highlight Create New Array and press Enter. 3. Highlight Configuration Method and press the spacebar to toggle to Automatic. 4. Review the proposed configuration of disk array and logical drive(s).
VessRAID 1000s Series Product Manual Creating a Disk Array – Express To create a disk array using the Express feature: 1. From the Main Menu, highlight Disk Array Management and press Enter. 2. Highlight Create New Array and press Enter. 3. Highlight Configuration Method and press the spacebar to toggle to Express. 4. Highlight Configuration Method and press to spacebar to choose each of the following characteristics for your disk array: • Redundancy • Capacity • Performance • Spare Drive 5.
Chapter 5: Management with the CLU Creating a Disk Array – Advanced For more information on the choices below, see “Chapter 8: Technology Background” on page 233. To create a disk array: 1. From the Main Menu, highlight Disk Array Management and press Enter. 2. Highlight Create New Array and press Enter. 3. Highlight Configuration Method and press the spacebar to toggle to Advanced. 4. Choose whether to enable Media Patrol and PDM. 5.
VessRAID 1000s Series Product Manual 17. Highlight Save Logical Drive and press Enter. 18. Review logical drive(s) you are about to create for your new array. Then do one of the following actions: • If you agree with the logical drive(s) as specified, highlight Complete Disk Array Creation and press Enter. A note will appear to remind you to set up LUN mapping for your new logical drive(s). Press any key to continue.
Chapter 5: Management with the CLU • Synchronizing – When you first create a disk array, the disk array synchronizes. During that time, your data is available. However, access will be slower until synchronizing is done. • Critical/Degraded – This condition results from a physical drive failure. Your data is still available. However, the disk array has lost redundancy (fault tolerance). You must determine the cause of the problem and correct it. See “Critical & Offline Disk Arrays” on page 290.
VessRAID 1000s Series Product Manual Enabling Media Patrol on a Disk Array Media Patrol checks the magnetic media on physical drives. To enable or disable Media Patrol: 1. From the Main Menu, highlight Disk Array Management and press Enter. 2. Highlight the disk array you want and press Enter. 3. Highlight Media Patrol and press the spacebar to toggle between Enable and Disable. 4. Press Ctrl-A to save your settings.
Chapter 5: Management with the CLU The available drives are either HDD or SSD, depending on the type of drives in the array. 6. Highlight Start and press Enter. Migrating a Disk Array In order to migrate RAID level, you may have to add physical drives. For more information, see “RAID Level Migration” on page 252. To migrate a disk array: 1. From the Main Menu, highlight Disk Array Management and press Enter. 2. Highlight the disk array you want and press Enter. 3.
VessRAID 1000s Series Product Manual The screen jumps to Disk Arrays Summary. Running PDM Be sure PDM must be enabled. See “Enabling PDM on a Disk Array” on page 154. To run Predictive Data Migration on a disk array: 1. From the Main Menu, highlight Disk Array Management and press Enter. 2. Highlight the disk array you want and press Enter. 3. Highlight Background Activities and press Enter. 4. Highlight Predictive Data Migration and press Enter. 5. Specify the source and target physical drives.
Chapter 5: Management with the CLU To locate a disk array: 1. From the Main Menu, highlight Disk Array Management and press Enter. 2. Highlight the disk array you want and press Enter. 3. Highlight Locate Disk Array and press Enter. The disk status LEDs for the physical drives in the disk array blink for one minute. Figure 8. Disk Status LED Disk Status Creating a Logical Drive You can create logical drives on existing disk arrays if there is available space in the array.
VessRAID 1000s Series Product Manual • Write Policy – Press spacebar to choose: Write Back or Write Through • Read Policy – Press spacebar to choose: No Cache, Read Cache, or Read Ahead Cache 6. Highlight Number of Axles and press the spacebar to choose the number of axles. Applies to RAID 50 and 60 only. 7. Press Ctrl-A to save your settings. Note If you did not use all of the available capacity of the disk array, you can create an additional logical drive at this point.
Chapter 5: Management with the CLU Managing Spare Drives Spare Drive Management includes the following functions: • Viewing a list of Spare Drives (page 159) • Creating a Spare Drive (page 159) • Making Spare Drive Settings (page 160) • Running Spare Check (page 160) • Deleting a Spare Drive (page 161) Viewing a list of Spare Drives To view a list of spare drives: From the Main Menu, highlight Spare Drive Management and press Enter.
VessRAID 1000s Series Product Manual Dedicated means this spare drive can only be used with the specified disk arrays. Global means this spare drive can be used by any disk array. 6. If you chose Dedicated, highlight Dedicated to Arrays and press the backspace key to erase the current value, then type the new value. Specify the number(s) of the disk array(s) you want to assign your spare. The current disk arrays are listed in parentheses.
Chapter 5: Management with the CLU Deleting a Spare Drive Caution If the spare drive you delete is the only spare, the controller will not rebuild a critical array until you provide a new spare drive. To delete a spare drive: 1. From the Main Menu, highlight Spare Drive Management and press Enter. A list of the current spare drives appears. 2. Highlight the spare drive you want to delete and press the spacebar to mark it. The mark is an asterisk (*) to the left of the listing. 3.
VessRAID 1000s Series Product Manual Managing Logical Drives The Logical Drive Management function deals with settings and functions of existing logical drives. To create or delete a logical drive, see “Managing Disk Arrays” on page 148.
Chapter 5: Management with the CLU 3. To set write cache policy for this logical drive, highlight WritePolicy and press the spacebar to toggle between WriteBack and WriteThru (write though). 4. Press Ctrl-A to save your settings. Setting Read Cache Policy To set read cache policy on a logical drive: 1. From the Main Menu, highlight Logical Drive Management and press Enter. 2. Highlight the logical drive you want and press Enter. 3.
VessRAID 1000s Series Product Manual Running Redundancy Check Redundancy Check is a maintenance procedure for logical drives in fault-tolerant disk arrays that ensures all the data matches exactly. To run Redundancy Check: 1. From the Main Menu, highlight Logical Drive Management and press Enter. 2. Highlight the logical drive you want and press Enter. 3. Highlight Background Activity and press Enter. 4. Highlight Start Redundancy Check and press Enter. The redundancy check parameters appear.
Chapter 5: Management with the CLU Managing the Network Connection The network connection deals with the VessRAID’s Management Port. • Making Management Port Settings (below) Making Management Port Settings When you log into the VessRAID over your network, you use the VessRAID’s management port. Before you change settings, please see “Choosing DHCP or a Static IP Address” on page 26. Making Automatic Settings 1. From the Main Menu, highlight Network Management and press Enter. 2.
VessRAID 1000s Series Product Manual Managing SAS Connections SAS connections deal with the VessRAID’s two host data ports. • Viewing SAS Port Information (page 166) • Making SAS Port Settings (page 166) • Viewing SAS Port Statistics (page 167) • Viewing SAS Initiators (page 167) • Adding a SAS Initiator (page 167) Viewing SAS Port Information There are two SAS data ports on the controller. To view information about the SAS ports: 1. From the Main Menu, highlight SAS Management and press Enter.
Chapter 5: Management with the CLU Viewing SAS Port Statistics There are two SAS data ports on the controller. To view information about the SAS ports: 1. From the Main Menu, highlight SAS Management and press Enter. 2. Highlight SAS Ports and press Enter. 3. Highlight the port you want to see and press Enter. 4. Highlight SAS Port Statistics and press Enter. The statistics for the selected port appear on the screen. Viewing SAS Initiators There are two SAS data ports on the controller.
VessRAID 1000s Series Product Manual Managing Background Activity Background activity refers to any of several functions that take place in the background while normal operation of the VessRAID continues. Background activities work in conjunction with disk arrays and logical drives. See “Managing Disk Arrays” on page 148 and “Managing Logical Drives” on page 162 for more information about how and when to use background activities.
Chapter 5: Management with the CLU • PDM – Looks for bad blocks on the physical drives of disk arrays • Transition – Returns a revertible spare drive to spare status • Synchronization – Checks the data integrity on disk arrays • Initialization – Sets all data bits in the logical drive to zero • Redundancy Check – Checks, reports and can correct data inconsistencies in logical drives The rates are defined as follows: 5. 6. • Low – Fewer resources to activity, more to data read/write.
VessRAID 1000s Series Product Manual Working with the Event Viewer The Event Viewer displays log of subsystem events. Events are classified as: • Runtime Events – A list of and information about the 1023 most recent runtime events recorded since the subsystem was started • NVRAM Events – A list of and information about most important events over multiple subsystem startups.
Chapter 5: Management with the CLU To display NVRAM events: 1. From the Main Menu, highlight Event Viewer and press Enter. 2. Highlight NVRAM Events and press Enter. The log of NVRAM Events appears. Events are added to the top of the list. Each item includes: 3. • Sequence number – Begins with 0 at system startup. • Device – Disk Array, Logical Drive, Physical Drive by its ID number.
VessRAID 1000s Series Product Manual Working with LUN Mapping LUN Mapping includes the following functions: • Viewing a List of Initiators (page 172) • Enabling LUN Mapping (page 172) • Creating an Initiator (page 172) • Mapping a LUN to an Initiator (page 173) • Deleting an Initiator (page 173) Viewing a List of Initiators LUN Mapping must be enabled in order for VessRAID to recognize a Fibre Channel or SAS initiator. To view a list of initiators: 1. 2.
Chapter 5: Management with the CLU A SAS initiator name is the SAS address of the HBA card in the Host PC. Obtain the initiator name from the initiator utility on your host system. Note that the initiator name you input must match exactly in order for the connection to work. 5. Press Ctrl-A to save the initiator. Note LUN Mapping must be enabled in order for VessRAID to recognize the initiator.
VessRAID 1000s Series Product Manual Managing UPS Units Uninterruptible Power Supply (UPS) Management includes the following functions: • Viewing a List of UPS Units (below) • Making UPS Settings (page 175) • Viewing UPS Information (page 176) Viewing a List of UPS Units To view a list of UPS units supporting the VessRAID: 1. From the Main Menu, highlight Additional Info and Management and press Enter. 2. Highlight UPS Management and press Enter.
Chapter 5: Management with the CLU Making UPS Settings These settings control how the VessRAID subsystem detects the UPS unit and responds to data reported by the UPS unit. To make UPS settings: 1. From the Main Menu, highlight Additional Info and Management and press Enter. 2. Highlight UPS Management and press Enter. 3. Highlight UPS Settings and press Enter. 4. Perform the following actions as required: • • • • 5. Verify the Current UPS Communication method: • USB – USB connection.
VessRAID 1000s Series Product Manual Figure 1. Notes 1. Detection Setting must be set to Auto. If a UPS is detected, the setting changes to Enable. 2. The maximum recommended Loading Ratio varies among models of UPS units. The general range is 60% to 80%. Viewing UPS Information To view information about a specific UPS unit: 1. From the Main Menu, highlight Additional Info and Management and press Enter. 2. Highlight UPS Management and press Enter. 3. Highlight the UPS unit you want and press Enter.
Chapter 5: Management with the CLU Managing Users User Management includes the following functions: • Viewing User Information (page 177) • Creating a User (page 177) • Changing a User’s Password (page 178) • Changing a User’s Display Name and Email Address (page 178) • Changing a User’s Privilege and Status (page 179) • Deleting a User (page 179) Viewing User Information Each user types their user name and password to log into the CLI. To view a list of current user accounts: 1. 2.
VessRAID 1000s Series Product Manual List of User Privileges • View – Allows the user to see all status and settings but not to make any changes • Maintenance – Allows the user to perform maintenance tasks including Rebuilding, PDM, Media Patrol, and Redundancy Check • Power – Allows the user to create (but not delete) disk arrays and logical drives, change RAID levels, change stripe size; change settings of components such as disk arrays, logical drives, physical drives, and the controller.
Chapter 5: Management with the CLU 6. Press Ctrl-A to save the settings. Changing a User’s Privilege and Status No user can change their own privilege or status. To change another user’s privilege or status. 1. Log in as the Administrator or a Super user. 2. From the Main Menu, highlight Additional Info and Management and press Enter. 3. Highlight User Management and press Enter. 4. Highlight a User in the list and press Enter. 5. Highlight Display Name and press Enter. 6.
VessRAID 1000s Series Product Manual Working with Software Management Software Management includes the following functions: • Making Email Settings (page 180) • Making SLP Settings (page 181) • Making Web Server Settings (page 181) • Making Telnet Settings (page 182) • Making SNMP Settings (page 182) • Managing SNMP Trap Sinks (page 183) • Making Netsend Settings (page 184) • Managing Netsend Recipients (page 184) Making Email Settings By default, Email service is set to Automatic and its n
Chapter 5: Management with the CLU Making SLP Settings By default, SLP service is set to Automatic and its normal status is Started. To make SLP service settings: 1. From the Main Menu, highlight Additional Info and Management and press Enter. 2. Highlight Software Management and press Enter. 3. Highlight SLP and press Enter. 4. Highlight Startup Type and press the spacebar to toggle between Automatic and Manual. 5. Press Ctrl-A to save your settings.
VessRAID 1000s Series Product Manual Making Telnet Settings By default, Telnet service is set to Automatic and its normal status is Started. To make Telnet service settings: 1. From the Main Menu, highlight Additional Info and Management and press Enter. 2. Highlight Software Management and press Enter. 3. Highlight Telnet and press Enter. 4. Highlight Startup Type and press the spacebar to toggle between Automatic and Manual. 5.
Chapter 5: Management with the CLU 6. Press Ctrl-A to save your settings. To start, stop or restart the SNMP service, highlight Start, Stop, or Restart and press Enter. Managing SNMP Trap Sinks Creating a SNMP trap sink To create a trap sink: 1. From the Main Menu, highlight Additional Info and Management and press Enter. 2. Highlight Software Management and press Enter. 3. Highlight SNMP and press Enter. 4. Highlight Trap Sinks and press Enter. A list of the current trap sinks appears.
VessRAID 1000s Series Product Manual Making Netsend Settings By default, Netsend service is set to Manual and its normal status is Stopped. To make Netsend service settings: 1. From the Main Menu, highlight Additional Info and Management and press Enter. 2. Highlight Software Management and press Enter. 3. Highlight Netsend and press Enter. 4. Highlight Startup Type and press the spacebar to toggle between Automatic and Manual. 5. Press Ctrl-A to save your settings.
Chapter 5: Management with the CLU 2. Highlight Software Management and press Enter. 1. Highlight the recipient whose settings you want to change and press Enter. 2. Type the recipient’s IP address into the field provided. 3. Highlight Message Event Severity Filter and press the spacebar to change severity levels. 4. Press Ctrl-A to save your settings. Deleting a Recipient To delete a recipient: 1. From the Main Menu, highlight Additional Info and Management and press Enter. 2.
VessRAID 1000s Series Product Manual Flashing through TFTP See “Chapter 7: Maintenance” on page 219 for instructions. Viewing Flash Image Information Flash image information refers to the package of firmware components running on your VessRAID controller, including: • Component name • Version number • Build date • Flash (installation) date To view flash image information: 1. From the Main Menu, highlight Additional Info and Management, and press Enter. 2.
Chapter 5: Management with the CLU Restoring Factory Defaults This function restores the factory default settings to the firmware and software items you select. Caution Use this function with care. Do not restore to default settings for any item unless you are sure this action is needed. To restore factory default settings: 1. From the Main Menu, highlight Additional Info and Management and press Enter. 2. Highlight Restore Factory Defaults and press Enter. 3.
VessRAID 1000s Series Product Manual Shutting Down the Subsystem There are two methods for shutting down the subsystem, depending on your connection. Choose the applicable procedure: • Shutting down the VessRAID – Telnet Connection (page 188) • Shutting down the VessRAID – Serial Connection (page 189) Important If you have a JBOD Expansion, always power off the RAID subsystem first. Then power off the JBOD subsystems.
Chapter 5: Management with the CLU • Caution After you power off the subsystem, wait at least 10 seconds before you power on the subsystem again. Shutting down the VessRAID – Serial Connection This function enables you to shutdown the VessRAID subsystem on a serial connection. You can only do part of this procedure in the CLU. Additional action is required, as described below. To shutdown the VessRAID: 1. From the Main Menu, highlight Additional Info and Management and press Enter. 2.
VessRAID 1000s Series Product Manual Starting Up After Shutdown There are two methods for shutting down the subsystem. Choose one: • Starting up the VessRAID – Telnet Connection (page 190) • Starting up the VessRAID – Serial Connection (page 190) Important If you have a JBOD Expansion, always power on the JBOD subsystems first. Then power on the RAID subsystem. Starting up the VessRAID – Telnet Connection To start the RAID subsystem: 1.
Chapter 5: Management with the CLU Restarting the Subsystem There are two methods for shutting down the subsystem, depending on your connection. Choose the applicable procedure: • Restarting the Subsystem (page 191) • Restarting VessRAID – Serial Connection (page 191) Note If you have a JBOD Expansion, you are not required to restart the JBOD subsystems when you restart the RAID subsystem.
VessRAID 1000s Series Product Manual 4. Highlight Submit and press Enter. A warning message appears. 5. Press Y to continue. The screen will display shutdown and startup functions. 6. When the Login: prompt appears, log into the CLU again.
Chapter 5: Management with the CLU Making Buzzer Settings This function enables the buzzer on the controller. When you first power-up the VessRAID, it beeps twice to show normal operation. To change buzzer settings: 1. From the Main Menu, highlight Buzzer and press Enter. A list of Controllers appears with the current buzzer setting and status. 2. Highlight the Controller whose buzzer you want to set and press Enter. 3. Highlight Enabled and press the spacebar to toggle between Yes and No. 4.
VessRAID 1000s Series Product Manual 194
Chapter 6: Management with the LCD Panel This chapter covers the following topics: • Using the LCD Panel (below) • Perusing the Interface (page 196) • Managing the Network Connection (page 198) • Managing SAS Connections (page 200) • Managing the Controller (page 202) • Managing Enclosures (page 203) • Managing Physical Drives (page 204) • Managing Disk Arrays (page 206) • Managing Spare Drives (page 215) Using the LCD Panel The LCD panel is optional and typically installed during VessRAID
VessRAID 1000s Series Product Manual Perusing the Interface • Making Mode Settings (page 196) • Simple Mode (page 196) • Advanced Mode (page 197) • Limitations (page 197) • Viewing Events (page 197) Making Mode Settings The LCD panel has two modes, Simple and Advanced. Simple is the default setting. The setting function toggles between Simple and Advanced mode. To make LCD mode settings: 1. Press the 2. Press the 3. Press the 4.
Perusing the Interface Advanced Mode Advanced Mode enables you to perform the Simple Mode functions, plus: • View Enclosure – View overall enclosure status.
VessRAID 1000s Series Product Manual Managing the Network Connection The network connection deals with the VessRAID’s Management Port. • Making Management Port Settings (below) Making Management Port Settings Manual IP Settings To make Management Port settings manually: 1. Press the 2. Press the or button until the display says Management Port. button and the display says Link Status Up. If it says Link Status Down, reconnect to the network before preceding. 3. 4.
Managing the Network Connection Automatic IP Settings To make Management Port settings automatically: 1. Press the 2. Press the or button until the display says Management Port. button and the display says Link Status Up. If it says Link Status Down, reconnect to the network before preceding. 3. Press the or button and the display says DHCP Disable. 4. Press the button to make a change. 5. Press the button to Enable. 6. Press the button to confirm.
VessRAID 1000s Series Product Manual Managing SAS Connections SAS connections deal with the VessRAID’s two host data ports. • Viewing SAS Port Information (page 200) • Making SAS Port Settings (page 200) To add a SAS initiator, see “Adding an Initiator” on page 68 (WebPAM PROe) or page 167 (CLU). Viewing SAS Port Information The SAS Controller has one SAS channel. The SAS channel has two ports.
Managing SAS Connections • 4. Press Press the 5. Press the 6. Press the button and the or button to choose SAS Port 2. button to scroll to Signal Strength. button to highlight the current value. or button to increment or decrement the value. The range is 1 to 8. 1 is the default. Signal strength correlates to cable length in meters. Example: If you have a 2 m SAS cable, set signal strength to 2. If performance is unsatisfactory try settings of 1 and 3, then use the best setting for your system.
VessRAID 1000s Series Product Manual Managing the Controller The RAID controller is the heart of the VessRAID subsystem. To view Controller statistics or to make Controller settings, see “Managing the Controller” on page 86 (WebPAM PROe) or page 137 (CLU). Viewing Controller Information To view information about the controller: 1. Press the 2. Press the 3. Press the or button until the display says View Controller. button and the display says Vendor.
Managing Enclosures Managing Enclosures The LCD panel provides information on the main VessRAID subsystem or Head Unit only. For a JBOD as well as other Enclosure functions, see “Managing Enclosures” on page 90 (WebPAM PROe) or page 140 (CLU). Viewing the Enclosure This function requires the LCD to be in Advanced mode. See page 196. To view enclosure information: 1. Press the or button until the display says View Enclosure. 2. Press the button and the display says Enclosure Status. 3.
VessRAID 1000s Series Product Manual Managing Physical Drives These functions require the LCD panel to be in Advanced mode. See page 196. Managing physical drives with the LCD includes: • Viewing Physical Drive Information (page 204) • Locating a Physical Drive (page 204) For other physical drive functions, see “Managing Physical Drives” on page 96 (WebPAM PROe) or page 145 (CLU). Viewing Physical Drive Information This function requires the LCD to be in Advanced mode. See page 196.
Managing Physical Drives 6. Press the button. The disk status LED for the physical drive blinks for one minute. See Figure 2. Figure 2.
VessRAID 1000s Series Product Manual Managing Disk Arrays Disk Array Management in the LCD includes the following functions: • Creating a Disk Array – Automatic (page 206) • Creating a Disk Array – Advanced (page 207) • Deleting a Disk Array (page 209) • Viewing Disk Array Information (page 209) • Locating a a Disk Array (page 210) • Creating a Logical Drive (page 211) • Deleting a Logical Drive (page 212) • Viewing Logical Drive Information (page 213) • Locating a a Logical Drive (page 21
Managing Disk Arrays Verifying To verify the results of the automatic disk array creation: 1. From the default screen, press the Logical Disk Management. or 2. Press the button and the display says 000. 3. Press the button again to choose this logical drive. 4. From the default screen, press the information for the logical drive.
VessRAID 1000s Series Product Manual 2. Press the button again and the display says 000. 3. Press the button again and the display says RAID Level. 4. Press the or button until the display shows the RAID level you want. Note that the available RAID levels depend on the number of physical drives in your disk array. 5. Press the button to choose the RAID level shown on the screen. The display shows the maximum available capacity. 6. Press the 7.
Managing Disk Arrays 2. Press the number. button again to display the available physical drives by 3. Press the button to move through the list. Press the choose a physical drive for your spare drive. button to Note that your spare drive must be the same type of drive, HDD or SSD, as the drives in your disk array. 4. Press the button again to confirm. The display shows the spare drive creation process. When the creation is finished, the LCD returns to Spare Drive Create.
VessRAID 1000s Series Product Manual 4. 5. Press the Press the button choose a disk array. or button to scroll through the list of items: • ID Number • Configured Capacity • Free Capacity • Number of Physical Drives* • Number of Logical Drives* • Status * Press the button to view physical drive or logical drive information from this point. Disk Array Status • OK – The normal state of a disk array. For RAID Levels other than RAID 0 (Striping), the disk array has full redundancy.
Managing Disk Arrays 6. Press the button. The disk status LEDs for the physical drives in the disk array blink for one minute. See Figure 3. Figure 3. Disk Status LED Disk Status Creating a Logical Drive You can create logical drives on existing disk arrays if there is available space in the array. For more information on the choices below, see “Chapter 8: Technology Background” on page 233. To create a logical drive from an existing disk array: 1. To Press the 2. Press the 3.
VessRAID 1000s Series Product Manual The display shows the default read policy. The choices are ReadCache, ReadAhead and None. 14. Press the 15. Press the or button until the display shows the read policy you want. button to choose the read policy shown on the screen. The display shows the default write policy. The choices are WriteBack and WriteThru (write though). 16. Press the or button until the display shows the write policy you want. 17.
Managing Disk Arrays Viewing Logical Drive Information This function requires the LCD to be in Advanced mode. See page 196. To view logical drive information: 1. Press the 2. Press the 3. Press the 4. Press the 5. Press the or button until the display says Logical Disk Management. button and the display a list of logical drives by ID number. or button to scroll through the list of logical drives. button choose a logical drive.
VessRAID 1000s Series Product Manual Locating a a Logical Drive This function requires the LCD to be in Advanced mode. See page 196. This feature helps you identify the physical drives assigned to the logical drive. To locate a logical drive: 1. Press the or button until the display says Logical Disk Management. 2. Press the 3. Press the 4. Press the 5. Press the 6. Press the button. The disk status LEDs for the physical drives in the logical drive blink for one minute. See Figure 4.
Managing Spare Drives Managing Spare Drives Spare Drive Management on the LCD includes: • Viewing Spare Drive Information (page 215) • Creating a Spare Drive (page 215) • Deleting a Spare Drive (page 216) • Locating a Spare Drive (page 216) For other spare drive functions, see “Managing Spare Drives” on page 124 or “Managing Spare Drives” on page 159. Viewing Spare Drive Information To view spare drive information: 1. Press the 2. Press the 3. Press the 4. Press the 5.
VessRAID 1000s Series Product Manual 2. Press the button and the display says Auto Configure. 3. Press the or button until the display says Advanced Configure. 4. Press the or button until the display says Spare Drive Create. 5. Press the 6. Press the or button to move through the list. Press the choose a physical drive for your spare drive. button again to display a list of unconfigured physical drives.
Managing Spare Drives 4. Press the button choose a spare drive. 5. Press the 6. Press the button. The disk status LED for the physical drive blinks for one minute. See Figure 5. or button until the display says Locate Spare Drive. Figure 5.
VessRAID 1000s Series Product Manual 218
Chapter 7: Maintenance This chapter covers the following topics: • Updating the Firmware in WebPAM PROe (below) • Updating the Firmware in the CLU (page 222) • Replacing a Power Supply (page 224) • Replacing a RAID Controller (page 225) • Replacing a Cooling Fan (page 226) • Replacing the Cache Battery (page 228) • Replacing the Memory Module (page 230) Updating the Firmware in WebPAM PROe A firmware update consists of the following actions: • Downloading the Firmware Image File (page 219) •
VessRAID 1000s Series Product Manual 5. Do one of the following actions: • Click the Download from TFTP Server option, then click the Next button. • From the Firmware Update tab dropdown menu, choose Download from TFTP Server. 6. Enter the hostname or IP address of your TFTP server in the field provided. 7. Enter the port number of your TFTP server in the field provided (69 is the default). 8. Enter the filename of the Firmware Update file in the field provided. 9. Click the Submit button. 10.
Chapter 7: Maintenance 6. Enter the filename of the Firmware Update file in the field provided. Or, click the Browse... button and choose the Firmware Update file in the Open dialog box. 7. 8. Click the Submit button. When the download is completed, click the Next button. A popup message appears to warn you not to reboot the VessRAID during the firmware update procedure. 9. In the popup message, click the OK button. The update progress displays.
VessRAID 1000s Series Product Manual When the controller shuts down, your WebPAM PROe connection will be lost. 9. Wait for two to three minutes. 10. In your browser, log into WebPAM PROe once again. If you cannot log in, wait for 30 seconds, and try again. Repeat until login is successful.
Chapter 7: Maintenance Restarting Subsystem over a Telnet Connection Warning Do not restart the VessRAID during a firmware upgrade procedure. Wait until the upgrade is done and you are prompted to restart. To restart the VessRAID subsystem on a Telnet connection: 1. From the Main Menu, highlight Additional Info and Management, and press Enter. 2. Highlight Shutdown or Restart and press Enter. 3. Press the spacebar to display Restart then press Enter. A warning message appears. 4.
VessRAID 1000s Series Product Manual Replacing a Power Supply VessRAID 1700s Series The power supply on the VessRAID 1700s Series is not replaceable onsite. If you need to replace the power supply, contact Technical Support and make arrangements to return the subsystem to Promise for service. See page 305. VessRAID 1800s Series The redundant power supplies on the VessRAID 1800s Series are designed as field-replaceable units. You can replace a power supply without removing the VessRAID from the rack.
Chapter 7: Maintenance Replacing a RAID Controller The RAID Controller monitors and manages the logical drives. When the controller is replaced, all of your logical drive data and configurations remain intact because this logical drive information is stored on the disk drives. RAID Controller failure is rare. But you might have to remove and reinstall the same RAID Controller in order to replace a cooling fan, cache battery, or memory module as described in this chapter.
VessRAID 1000s Series Product Manual See page 228 and page 230 for more information. 2. Carefully slide the new RAID Controller into the enclosure. 3. Swing the latch to the left and secure it with the thumbscrew. 4. Reconnect the SAS, Ethernet, serial, and power cables. 5. Switch on the power. The VessRAID restarts. For more information about VessRAID’s start-up behavior, see “Connecting the Power” on page 21. This completes the RAID Controller replacement procedure.
Chapter 7: Maintenance Figure 3. RAID Controller cover and attaching screw Cover Attaching screw (one each side) 4. Remove the four attaching screws. See Figure 4. 5. Detach the fan’s power connector and lift the old fan out of the controller. Figure 4. RAID Controller cooling fan Power connectors 6. 7. Attaching screws (4) Place a new fan in the controller, attach the power connector, and install the four attaching screws. Attach the RAID Controller cover and install the two attaching screws.
VessRAID 1000s Series Product Manual 8. Reinstall the RAID Controller. See “Replacing a RAID Controller” on page 225. This completes the fan replacement procedure. Replacing the Cache Battery The cache battery, or Battery Backup Unit (BBU), is located inside the RAID Controller. The battery assembly is replaced as a unit. Cautions • Try reconditioning the battery before you replace it. See page 94 or page 143 for more information.
Chapter 7: Maintenance 4. Lay the RAID Controller on a non-static surface and remove the cover attaching screws, one on each side, then remove the cover. 5. Remove the battery assembly attaching screw on the outside of the RAID controller housing. 6. Detach the battery connector and remove the battery assembly. See page 227, Figure 3. Figure 6.
VessRAID 1000s Series Product Manual Figure 7. Battery connector pins No pin Blank 8. Put the battery assembly into place and install the attaching screw. 9. Replace the RAID Controller cover and install the two attaching screws. See page 227, Figure 3. 10. Reinstall the RAID Controller. See “Replacing a RAID Controller” on page 225. This completes the cache battery replacement procedure.
Chapter 7: Maintenance Figure 8. Removing the RAID Controller Thumbscrew Latch 2. Lay the RAID Controller on a non-static surface and remove the cover attaching screws, one on each side, then remove the cover. 3. Gently press the retainers outward until the memory module pops out of the memory slot. See page 227, Figure 3. Figure 9. RAID Controller memory module Retainer Memory module Alignment groove Memory slot Retainer 4.
VessRAID 1000s Series Product Manual 232
Chapter 8: Technology Background This chapter covers the following topics: • Introduction to RAID (below) • Choosing a RAID Level (page 244) • Choosing Stripe Size (page 247) • Choosing Sector Size (page 247) • Cache Policy (page 248) • Capacity Coercion (page 250) • Initialization (page 251) • Hot Spare Drive(s) (page 251) • Partition and Format the Logical Drive (page 252) • RAID Level Migration (page 252) • Media Patrol (page 259) • Predictive Data Migration (PDM) (page 260) • Tr
VessRAID 1000s Series Product Manual RAID 0 – Stripe When a logical drive is striped, the read and write blocks of data are interleaved between the sectors of multiple physical drives. Performance is increased, since the workload is balanced between drives or “members” that form the logical drive. Identical drives are recommended for performance as well as data storage efficiency. Figure 1.
Chapter 8: Technology Background RAID 1 – Mirror When a logical drive is mirrored, identical data is written to a pair of physical drives, while reads are performed in parallel. The reads are performed using elevator seek and load balancing techniques where the workload is distributed in the most efficient manner. Whichever drive is not busy and is positioned closer to the data will be accessed first.
VessRAID 1000s Series Product Manual RAID 1E – Enhanced Mirror RAID 1E offers the security of mirrored data provided by RAID 1 plus the added capacity of more than two physical drives. It also offers overall increased read/ write performance plus the flexibility of using an odd number of physical drives. With RAID 1E, each data stripe is mirrored onto two physical drives. If one drive fails or has errors, the other drives continue to function, providing fault tolerance. Figure 3.
Chapter 8: Technology Background RAID 5 – Block and Parity Stripe RAID 5 organizes block data and parity data across the physical drives. Generally, RAID Level 5 tends to exhibit lower random write performance due to the heavy workload of parity recalculation for each I/O. RAID 5 is generally considered to be the most versatile RAID level. It works well for file, database, application and web servers. Figure 4.
VessRAID 1000s Series Product Manual RAID 6 – Block and Double Parity Stripe RAID level 6 stores dual parity data is rotated across the physical drives along with the block data. A RAID 6 logical drive can continue to accept I/O requests when any two physical drives fail. Figure 5. RAID 6 stripes all drives with data and dual parity Double Distributed (Wide-space Q+Q) Parity Data Blocks Physical Drives Hence, a RAID 6 logical drive with (7) 100 GB physical drives will have a capacity of 500 GB.
Chapter 8: Technology Background RAID 10 – Mirror / Stripe Mirror + Stripe combines both of the RAID 1 and RAID 0 logical drive types. RAID 10 can increase performance by reading and writing data in parallel— striping—while protecting data by duplicating it—mirroring. Promise implements RAID 10 by creating a data stripe over one pair of disk drives, then mirroring the stripe over a second pair of disk drives. Some applications refer to this method as RAID 0+1. Figure 6.
VessRAID 1000s Series Product Manual RAID 50 – Striping of Distributed Parity RAID 50 combines both RAID 5 and RAID 0 features. Data is striped across physical drives as in RAID 0, and it uses distributed parity as in RAID 5. RAID 50 provides data reliability, good overall performance, and supports larger volume sizes. Figure 7.
Chapter 8: Technology Background RAID 50 Axles When you create a RAID 50, you must specify the number of axles. An axle refers to a single RAID 5 logical drive that is striped with other RAID 5 logical drives to make RAID 50. An axle can have from 3 to 16 physical drives, depending on the number of physical drives in the logical drive. The chart below shows RAID 50 logical drives with 6 to 16 physical drives, the available number of axles, and the resulting distribution of physical drives on each axle.
VessRAID 1000s Series Product Manual RAID 60 – Striping of Double Parity RAID 60 combines both RAID 6 and RAID 0 features. Data is striped across disks as in RAID 0, and it uses double distributed parity as in RAID 6. RAID 60 provides data reliability, good overall performance and supports larger volume sizes. Figure 8. RAID 60 is a combination of RAID 6 and RAID 0 Double Distributed Parity Axle 1 Data Stripes Axle 2 Disk Drives Figure 9.
Chapter 8: Technology Background RAID 60 Axles When you create a RAID 60, you must specify the number of axles. An axle refers to a single RAID 6 logical drive that is striped with other RAID 6 logical drives to make RAID 60. An axle can have from 4 to 16 physical drives, depending on the number of physical drives in the logical drive. The chart below shows RAID 60 logical drives with 8 to 20 physical drives, the available number of axles, and the resulting distribution of physical drives on each axle.
VessRAID 1000s Series Product Manual Choosing a RAID Level There are several issues to consider when choosing the RAID Level for your VessRAID disk array. The following discussion summarizes some advantages, disadvantages, and applications for each choice.
Chapter 8: Technology Background RAID 1E Advantages Disadvantages Implemented as a mirrored disk array whose segments are RAID 0 disk arrays High I/O rates are achieved thanks to multiple stripe segments Can use an odd number of disks Very high disk overhead - uses only 50% of total capacity Recommended Applications for RAID 1E • Imaging applications • Database servers • General file server RAID 5 Advantages Disadvantages High Read data transaction rate Medium Write data transaction rate Good a
VessRAID 1000s Series Product Manual RAID 10 Advantages Disadvantages Implemented as a mirrored disk array whose segments are RAID 0 disk arrays High I/O rates are achieved thanks to multiple stripe segments Very high disk overhead - uses only 50% of total capacity Recommended Applications for RAID 10 • Imaging applications • Database servers • General file server RAID 50 Advantages Disadvantages High Read data transaction rate Medium Write data transaction rate Good aggregate transfer rate Hig
Chapter 8: Technology Background Choosing Stripe Size Stripe Size, also called “Stripe Block Size”, refers to the size of the data blocks written to, and read from, the physical drives. Stripe Size is specified when you create a disk array. In order to change the Stripe Size of an existing disk array, you must delete the disk array and create a new one. You can choose Stripe Size directly when you use the Advanced function to create a disk array.
VessRAID 1000s Series Product Manual • Linux operating systems with the 2.6 kernel support 64-bit LBA. For these OSes, always choose the default 512 B sector size. 2 TB Limitation If your Host PC runs Windows 2000 or Windows XP (32-bit), and you want to create logical drives larger than 2TB, you must choose a sector size larger than 512 B when you create the logical drive. The table below correlates sector size with logical drive capacity.
Chapter 8: Technology Background Read Cache Policy • Read Cache – The read cache is enabled. • Read Ahead – The read cache and the read-ahead feature are enabled. Read-ahead anticipates the next read and performs it before the request is made. Can increase read performance. • No Cache – The read cache is disabled. Write Cache Policy • Write Back – Data is written first to the cache, then to the logical drive. Better performance.
VessRAID 1000s Series Product Manual To enable the Adaptive Writeback Cache option, see “Making Controller Settings” on page 87 (WebPAM PROe) or page 137 (CLU). Also see “Replacing the Cache Battery” on page 228. Capacity Coercion This feature is designed for fault-tolerant logical drives (RAID 1, 1E, 5, 10, 50, and 60). It is generally recommended to use physical drives of the same size in your disk arrays.
Chapter 8: Technology Background Initialization Initialization is done to logical drives after they are created from a disk array. Initialization sets all data bits in the logical drive to zero. The action is useful because there may be residual data on the logical drives left behind from earlier configurations. For this reason, Initialization is recommended for all new logical drives. See “Initializing a Logical Drive” on page 120 (WebPAM PROe) or page 163 (CLU).
VessRAID 1000s Series Product Manual Partition and Format the Logical Drive Like any other type of fixed disk media in your system, a RAID logical drive must also be partitioned and formatted before use. Use the same method of partitioning and formatting on an logical drive as you would any other fixed disk. Depending on the operating system you use, there may or may not be various capacity limitations applicable for the different types of partitions.
Chapter 8: Technology Background RAID 0 A RAID 0 source logical drive can migrate to the following target logical drives: Target Requirements RAID 0 Add physical drives. RAID 1 2 physical drives only. Only a single-drive RAID 0 can migrate to RAID 1 by adding 1 physical drive. RAID 1E 3 or more physical drives. If existing physical drives have no unused space, add 1 or more physical drives. RAID 5 3 physical drives minimum, 32 maximum. RAID 0 must have less than 16 physical drives.
VessRAID 1000s Series Product Manual RAID 1 A RAID 1 Source logical drive can migrate to the following Target logical drives: Target Requirements RAID 0 None. RAID 1E 3 or more physical drives. Add 1 or more physical drives. RAID 5 3 physical drives minimum, 32 maximum. Add 1 or more physical drives. RAID 10 4 physical drives minimum. Even number of physical drives. Add 2 or more physical drives. RAID 50 6 physical drives minimum, 32 per axle maximum. Add 4 or more physical drives.
Chapter 8: Technology Background RAID 5 A RAID 5 Source logical drive can migrate to the following Target logical drives: Target Requirements RAID 0 None. RAID 1E None. RAID 5 Add physical drives. 32 maximum. RAID 6 4 physical drives minimum, 32 maximum. If existing physical drives have no unused space, add 1 or more physical drives. RAID 10 4 physical drives minimum. Even number of physical drives. If existing physical drives have no unused space, add 1 or more physical drives.
VessRAID 1000s Series Product Manual RAID 10 A RAID 10 Source logical drive can migrate to the following Target logical drives: Target Requirements RAID 0 None. RAID 1E None. RAID 5 3 physical drives minimum, 32 maximum. RAID 10 must have less than 16 physical drives. RAID 6 4 physical drives minimum, 32maximum. RAID 10 must have less than 32 physical drives. If existing physical drives have no unused space, add 1 or more physical drives. RAID 10 Add physical drives.
Chapter 8: Technology Background RAID 50 A RAID 50 Source logical drive can migrate to the following Target logical drives: Target Requirements RAID 0 None. RAID 1E None. RAID 5 32 physical drives maximum. RAID 50 must have less than 32 physical drives. RAID 6 32 physical drives maximum. RAID 50 must have less than 16 physical drives. If existing physical drives have no unused space, add 1 or more physical drives. RAID 10 Even number of physical drives. RAID 50 Add physical drives.
VessRAID 1000s Series Product Manual Important • The Target disk array may require more physical drives than the Source disk array • If the Target disk array requires an EVEN number of physical drives but the Source disk array has an ODD number, ADD a physical drive as part of the migration process • You cannot reduce the number of physical drives in your disk array, even if the Target disk array requires fewer physical drives than the Source disk array • RAID 1 (mirroring) works with two drives onl
Chapter 8: Technology Background Current LD Size Maximum LD Expansion Size 8 to 16 TB 16 TB 4096 bytes 4 to 8 TB 8 TB 2048 bytes 2 to 4 TB 4 TB 1024 bytes up to 2 TB 2 TB 512 bytes Sector Size At this point, you have the choice of: • Format the unpartitioned/unformatted capacity as a second logical drive • Delete the existing disk array and create a new one in the desired size Delete and Recreate If you require a logical drive larger than the maximum expansion size: 1.
VessRAID 1000s Series Product Manual Predictive Data Migration (PDM) Predictive Data Migration (PDM) is the migration of data from the suspect disk drive to a spare disk drive, similar to Rebuilding a Logical Drive. But unlike Rebuilding, PDM constantly monitors your disk drives and automatically copies your data to a spare disk drive before the disk drive fails and your Logical Drive goes Critical. See “Running PDM” on page 56 (WebPAM PROe) or page 156 (CLU).
Chapter 8: Technology Background Transition The Transition feature enables you to specify “permanent” spare drives for your VessRAID subsystem. Transition is the process of replacing a revertible spare drive that is currently part of a disk array with an unconfigured physical drive or a non-revertible spare. The revertible spare drive returns to its original status. Transition happens automatically when the following sequence of events takes place: • You create a revertible spare drive.
VessRAID 1000s Series Product Manual Example Following is an example to explain the Transition function. In the example above, there is a four-drive RAID 5 disk array and a global spare drive. Physical drives 1, 2, 3, and 4 belong to the disk array. Physical drive 5 remains unconfigured. Physical drive 6 is a revertible spare drive. If a physical drive fails in a disk array and there is a spare drive of adequate capacity available, the controller automatically rebuilds the array using the spare drive.
Chapter 8: Technology Background There is no spare drive at this moment. Even if physical drive 5 is of adequate capacity, it has not been designated as a spare, therefore the controller cannot use it as a spare. Automatic Transition At this juncture, you would replace the failed drive in slot 3 with a new one of the same or greater capacity.
VessRAID 1000s Series Product Manual 264
Chapter 9: Troubleshooting This chapter covers the following topics: • VessRAID is Beeping (below) • LEDs Display Amber or Red (page 266) • CLU Reports a Problem (page 270) • WebPAM PROe Reports a Problem (page 272) • LCD Panel Reports a Problem (page 275) • Viewing a Report from OPAS (page 275) • Event Notification Response (page 277) • Critical & Offline Disk Arrays (page 290) • Incomplete Array (page 293) • Physical Drive Problems (page 294) • Enclosure Problems (page 296) • Connec
VessRAID 1000s Series Product Manual • If email notification is enabled, check for new messages. • Check for yellow !s • Check the event log. See page 47 or page 170. red Xs in Tree View, see page 272. When a continuous tone sounds, there are multiple alarm patterns sounding at the same time. To make alarm settings or cancel an alarm, see “Making Buzzer Settings” on page 94 or page 193.
Chapter 9: Troubleshooting State LEDs Dark Steady Green Flashing Green Amber Red System Off Normal — — — Global RAID System Off Status Normal — Logical Logical Drive Critical Drive Offline Normal Locating the Enclosure Fan, battery, power supply, temperature, or voltage problem* Power Global Enclosure Status System Off Controller Activity System Off One or more or no SAS SAS ports ports connected connected Activity — — Controller Heartbeat System Off Normal* — — — * Check the
VessRAID 1000s Series Product Manual The Power/Activity LED flashes during drive activity. The Disk Status LED displays Green when a drive is present and configured. State LEDs Dark Steady Green Flashing Green Amber Red Power/ Activity No Drive Drive Present Activity — — Status No Drive or Unconfigured Drive OK Locating the Drive Drive Rebuilding Array Drive Offline See “Critical & Offline Disk Arrays” on page 290 for a discussion of rebuilding and failed disk drives.
Chapter 9: Troubleshooting Figure 5.
VessRAID 1000s Series Product Manual If the Controller Status LED continues to display amber after startup, contact Promise Technical Support. See page 305. The Dirty Cache LED flashes during input/output operation. If the LED shines amber and the power is off, there is unsaved data in the cache. Do NOT power down the VessRAID while this LED is on. See “Browser Does Not Connect to WebPAM PROe” on page 301 for more information. If the battery LED is amber or red, try reconditioning the battery.
Chapter 9: Troubleshooting To display NVRAM events: 1. From the Main Menu, highlight Event Viewer and press Enter. 2. Highlight NVRAM Events and press Enter. The log of NVRAM Events appears. Events are added to the top of the list. Each item includes: 3. • Sequence number – Begins with 0 at system startup. • Device – Disk Array, Logical Drive, Physical Drive by its ID number.
VessRAID 1000s Series Product Manual Physical Drives in the Array Logical Drives in the Array [Locate Disk Array] Save Settings [CTRL-A] Restore Settings [CTRL-R] Return to Previous Menu From this screen: • Highlight Physical Drives in the Array and press Enter to identify the failed disk drive • Highlight Rebuild and press Enter to rebuild the array after you replace the failed disk drive For more information, see “Critical & Offline Disk Arrays” on page 290.
Chapter 9: Troubleshooting To set up email and popup message notification, see “Setting-up User Event Subscriptions” on page 61. Figure 7. An example of a popup message • Keeps a record in the Event Log. Figure 8. The Event Log • Keeps a record in the Event Log. • Displays full information in Management View.
VessRAID 1000s Series Product Manual Figure 9.
Chapter 9: Troubleshooting LCD Panel Reports a Problem The LCD panel can report a certain problems, including a Critical logical drives. Figure 10.The optional LCD panel reports a Critical logical drive Press the or button until you see the View Events menu. Then press the button to read the corresponding event. The event gives specific information, such as which physical drive failed or was removed. Viewing a Report from OPAS The VessRAID subsystem comes with One Plug Auto Service (OPAS).
VessRAID 1000s Series Product Manual 4. Open the root folder of the USB stick and copy the file subinfo_xxxxxxxxxx.log to the PC desktop or a convenient location. Figure 12.Locating the report file on the USB stick 5. Open the subinfo_xxxxxxxxxx.log file in a text editor to read the system profile and diagnostic report. Note Choose a text editor with some word processor capability, such as WordPad on a Windows PC, for easier viewing.
Chapter 9: Troubleshooting Event Notification Response When you choose Event Notification, WebPAM PROe sends popup and/or email messages regarding its status. The messages you see depend on your notification selection and what is currently happening in the VessRAID. See “Setting-up User Event Subscriptions” on page 61.
VessRAID 1000s Series Product Manual Reported Event Corrective Action Battery is discharging Battery is undergoing reconditioning. Battery is charging Battery is being recharged. Battery reconditioning is complete Battery reconditioning is finished. Battery is malfunctioning Run battery reconditioning. Run battery reconditioning. See page 94 (WebPAM PROe) or page 143 (CLU). If this message reappears, replace the battery. Battery reconditioned successfully Battery reconditioning is finished.
Chapter 9: Troubleshooting Reported Event Blowers are functioning normally Corrective Action Normal. Blowers are NOT installed Reinstall the fan. If the fan does not turn, replace it. See page 226. Blower status is unknown Check for airflow out of the cooling unit. If there is none, check for proper installation. Cache BBU flushing has started VessRAID’s cache is being flushed. BBU flushing has ended VessRAID’s cache has been flushed. BBU flushing has failed VessRAID’s cache could not be flushed.
VessRAID 1000s Series Product Manual Reported Event Corrective Action Drive Interface Controller Drive-interface controller found Normal. Drive-interface controller is NOT found Restart the VessRAID. See page 85 (WebPAM PROe) or page 191 (CLU). If this message appears repeatedly, contact Technical Support. See page 305. Drive-interface diagnostics has passed Normal. Drive-interface diagnostics has failed Restart the VessRAID. See page 85 (WebPAM PROe) or page 191 (CLU).
Chapter 9: Troubleshooting Reported Event Corrective Action Host-interface controller has encountered an unrecoverable error Restart the VessRAID. See page 85 (WebPAM PROe) or page 191 (CLU). Host-interface controller has received an aborttask/ abort task set/clear task set command. Result of user action. Normal. Host-interface controller has received an clear ACA command. Result of clearing an auto contingent alliance condition. If this message appears repeatedly, contact Technical Support.
VessRAID 1000s Series Product Manual Reported Event Corrective Action Logical drive initialization Initialization stopped because of user intervention, has stopped schedule or the logical drive was deleted or went critical or offline. Logical drive initialization Initialization failure due to a failed disk drive. Replace marks the logical drive the disk drive, delete and recreate the logical drive. offline See page 105 (WebPAM PROe) or page 148 (CLU).
Chapter 9: Troubleshooting Reported Event Corrective Action Media patrol is queued Media patrol has been set manually or by schedule. Media patrol is stopped internally Media patrol stopped because the disk array was deleted or removed. Online Capacity Expansion Online capacity expansion has started Result of settings or user action. Normal. Online capacity Normal.
VessRAID 1000s Series Product Manual Reported Event Corrective Action PDM is stopped internally The destination drive was removed or used for a rebuild. Physical Disk Physical disk is marked online Disk drive restored to normal operation. Physical disk is marked online Disk drive removed from service due to errors. If necessary, try to force the disk online. See page 100 (WebPAM PROe) or page 147 (CLU). Physical disk is marked as dead. Disk drive failure. Replace the disk drive.
Chapter 9: Troubleshooting Reported Event Physical disk negotiation speed is decreased. Corrective Action Disk drive had to reduce its data rate. If this message appears repeatedly, replace the disk drive. Previously configured disk Disk drive may have failed or was removed from the is no longer found enclosure. Replace or reinstall the disk drive as needed. A physical disk has Disk drive experienced an unknown error. If this encountered an unknown message appears repeatedly, replace the disk drive.
VessRAID 1000s Series Product Manual Reported Event PSU 12V/5V/3.3V power is within the range Corrective Action Normal. RAID Level Migration RAID Level migration is started Result of settings or user action. Normal. RAID Level migration is completed Normal. RAID Level migration is paused Migration paused because of user intervention, schedule or a higher priority background activity. RAID Level migration is resumed Migration has resumed again after a pause.
Chapter 9: Troubleshooting Reported Event Corrective Action Rebuild is resumed Rebuild has resumed again after a pause. Rebuild is stopped Rebuild stopped because of user intervention, schedule or the logical drive was deleted or the target disk drive encountered an error. If rebuild stopped by the user, restart the rebuild. See page 114 (WebPAM PROe) or page 154 (CLU). Rebuild stopped internally The logical drive is offline. See page 290. Rebuild is aborted due to System resources are low.
VessRAID 1000s Series Product Manual Reported Event Corrective Action Resource Resource is NOT available System resources are low. Reduce system load or restart the VessRAID. See page 85 (WebPAM PROe) or page 191 (CLU). Spare Check Spare check started on the given spare drive Result of settings or user action. Normal. Spare check completed Normal. successfully on the given spare drive Spare Drives Physical disk assigned as Result of settings or user action. Normal.
Chapter 9: Troubleshooting Reported Event Synchronization is stopped Corrective Action Synchronization stopped because of user intervention, schedule or the logical drive was deleted or went critical or offline. Synchronization is System resources are low. Reduce system load or aborted due to an internal restart the VessRAID. See page 85 (WebPAM PROe) error. or page 191 (CLU). Synchronization is queued Synchronization is already running on another logical drive in the same array.
VessRAID 1000s Series Product Manual Critical & Offline Disk Arrays A fault-tolerant disk array—RAID 1, 1E, 5, 10, and 50—goes critical when a disk drive is removed or fails. A RAID 6 or 60 disk array—goes degraded when a disk drive is removed or fails and critical when two disk drives are removed of fail. Due to the fault tolerance of the disk array, the data is still available and online.
Chapter 9: Troubleshooting • The Disk Status LED changes from green to red. Figure 14.VessRAID disk drive carrier LEDs Disk Status Power/Activity • The audible alarm repeatedly sounds two short beeps. See page 265. • WebPAM PROe reports the condition. See page 272. Also see “Physical Drive Problems” on page 294.
VessRAID 1000s Series Product Manual To enable Automatic Rebuild, see “Making Background Activity Settings” on page 54 (WebPAM PROe) or page 168 (CLU). To set Hot Spare Policy, see “Making Spare Drive Settings” on page 126 (WebPAM PROe) or page 160 (CLU). Important If your replacement disk drive was formerly part of a different disk array or logical drive, you must clear the configuration data on the replacement drive before you use it. See page 99 (WebPAM PROe) or page 146 (CLU).
Chapter 9: Troubleshooting Incomplete Array An incomplete array can result from any of the following conditions: • The NVRAM watermark for the RAID level migration currently in progress is missing or cannot be found • A physical drive goes missing during transport See “Physical Drive Failed” on page 294 for more information.
VessRAID 1000s Series Product Manual Physical Drive Problems Physical Drive Offline Check the drive for: • PFA Condition – Caused by a bad block or sector. See “Clearing Stale and PFA Conditions” on page 99 (WebPAM PROe) or page 146 (CLU). • Stale Configuration – Caused by obsolete array information on the physical drive. Identify the disk array to which the physical drive belongs. Then delete the disk array. See “Deleting a Disk Array” on page 110 (WebPAM PROe) or page 152 (CLU).
Chapter 9: Troubleshooting You can set the VessRAID to migrate disk arrays under Non-Volatile Random Access Memory (NVRAM), a much faster process because it writes data to the memory in the controller. However, if a physical drive or the controller fails during migration, the logical drives will go offline and you will lose data. See “Incomplete Array” on page 293. Because the setting for migration under NVRAM requires special access, most users will not encounter this condition.
VessRAID 1000s Series Product Manual Enclosure Problems WebPAM PROe displays yellow !s components that need attention. red Xs in Tree View to identify When a yellow ! appears over a Subsystem in Tree View, click the Enclosure icon. The Enclosure screen will display (below). Figure 16.Enclosure information in Management View In this example, one of the RAID Controller fans has failed. The Enclosure Diagram displays color and motion changes to identify the failed fan.
Chapter 9: Troubleshooting Enclosure Overheat Overheating is a potentially serious condition because the excessively high temperatures can lead to disk drive failure and controller malfunction. Overheating usually results from: • Fan failure • Poor air circulation around the enclosure Fan Failure On VessRAID, there are two kinds of fans: • Power supply fan • RAID Controller fan If a power supply fan fails, you must replace the power supply. If a RAID Controller fan fails, you can replace it onsite.
VessRAID 1000s Series Product Manual Power Supply VessRAID 1800s Series VessRAID 1800s Series has two power supplies. The advantage of two power supplies is that, should one fail, the other will continue powering the subsystem. The power supplies are hotswappable. VessRAID 1700s Series VessRAID 1700s Series has only one power supply and it is not replaceable onsite. If you need to replace the power supply, contact Technical Support and make arrangements to return the subsystem to Promise for service.
Chapter 9: Troubleshooting Connection Problems When you install your Promise product following the instructions in the Quick Start Guide and this Product Manual, you should have little trouble getting your equipment to work the first time. But connection problems can arise that are not the User's or Installer's fault. Every conceivable problem cannot be covered in the documentation but some guidelines could be helpful. Connection problems cause a majority of failures in almost any electrical system.
VessRAID 1000s Series Product Manual Network Connections Each controller has an Ethernet (RJ45) Management Port connector on the back of the enclosure. This is a Gigabit Ethernet connector designed to connect to your network. The VessRAID becomes a node on your network like any other PC, server or other component with an IP address. VessRAID ships from the factory a default Management Port IP address of 192.168.0.1. You must change this address to one that will work with your network.
Chapter 9: Troubleshooting Browser Does Not Connect to WebPAM PROe If you successfully setup and connected to WebPAM PROe, then suddenly you can no longer connect, it might be the result of the following three conditions: • DHCP is enabled on your VessRAID’s management port • The DHCP server does not have a dedicated IP address for the VessRAID • The VessRAID restarted and your DHCP server assigned a new IP address You must obtain the new IP Address for the management port in order to direct your bro
VessRAID 1000s Series Product Manual Unsaved Data in the Controller Cache The Dirty Cache LED informs you that there is data in the cache that has not been saved to non-volatile memory. Such data is sometimes called “dirty,” not to suggest it is corrupted in some way but because it has not been saved to a disk drive. Figure 19.Dirty Cache LED Dirty Cache LED If there is unsaved data in the controller’s cache, the Dirty Cache LED shines amber. During this time, do NOT power down the VessRAID.
Chapter 10: Support • Frequently Asked Questions (below) • Contacting Technical Support (page 305) • Limited Warranty (page 309) • Returning the Product For Repair (page 311) Frequently Asked Questions What kind of disk drives can I use with VessRAID? VessRAID supports 3.0 GB/s Serial ATA disk drives and 3.0 Gb/s SAS drives. VessRAID does not support Parallel ATA (PATA) disk drives.
VessRAID 1000s Series Product Manual WebPAM PROe connection was working OK. But later on, it timed out. What do I do now? The network condition can time-out for several reasons. When an open connection has no action for a specific amount of time (the Administrator can change it), the connection times-out automatically for security reasons. When you attempt to use WebPAM, it returns to the login screen. Enter your user name and password and click Login, and WebPAM will establish a new connection.
Chapter 10: Support How can I be sure everything is working OK on the VessRAID? Locally: The VessRAID enclosure has LEDs on the front to monitor the status of power, field replaceable units (FRUs) and logical drives. When these are green, VessRAID is functioning normally. Remotely: Check the Tree Icons in WebPAM. If there are no yellow or red warning icons displayed, VessRAID is functioning normally.
VessRAID 1000s Series Product Manual Technical Support Services Promise Online™ Web Site http://www.promise.com/support/ support_eng.asp (technical documents, drivers, utilities, etc.) United States E-mail Support e-Support On-Line Fax Support +1 408 228 1100 Attn: Technical Support Phone Support +1 408 228 1400 option 4 If you wish to write us for support: Promise Technology, Inc.
Chapter 10: Support Italy E-mail Support e-Support On-Line Fax Support +39 0 6 367 124 00 Attn: Technical Support Phone Support +39 0 6 367 126 26 If you wish to write us for support: Promise Technology Italy Piazza del Popolo 18 00187 Roma, Italia Taiwan E-mail Support e-Support On-Line Fax Support +886 3 578 2390 Attn: Technical Support Phone Support +886 3 578 2395 ext. 8825 or 8826 If you wish to write us for support: Promise Technology, Inc. 2F, No. 30, Industry E. Rd.
VessRAID 1000s Series Product Manual China E-mail Support e-Support On-Line Fax Support +86 10 8857 8015 Attn: Technical Support Phone Support +86 10 8857 8085 or 8095 If you wish to write us for support: Promise Technology China – Beijing Room 1205, Tower C Webok Time Center, No.
Chapter 10: Support Limited Warranty Promise Technology, Inc. (“Promise”) warrants that this product, from the time of the delivery of the product to the original end user: a) all components, except the cache backup battery, for a period of three (3) years; b) the cache backup battery, for a period of one (1) year; c) will conform to Promise’s specifications; d) will be free from defects in material and workmanship under normal use and service.
VessRAID 1000s Series Product Manual Promise DOES NOT WARRANT that any product is free from errors or that it will interface without problems with your computer system. It is your responsibility to back up or otherwise save important data before installing any product and continue to back up your important data regularly. No other document, statement or representation may be relied on to vary the terms of this limited warranty.
Chapter 10: Support Returning the Product For Repair If you suspect a product is not working properly, or if you have any questions about your product, contact our Technical Support Staff through one of our Technical Services, making sure to provide the following information: • Product model and serial number (required) • Return shipping address • Daytime phone number • Description of the problem • Copy of the original purchase invoice The technician will assist you in determining whether the pro
VessRAID 1000s Series Product Manual You are responsible for the cost of insurance and shipment of the product to Promise. Note that damage incurred due to improper transport or packaging is not covered under the Limited Warranty. When repairing returned product(s), Promise may replace defective parts with new or reconditioned parts, or replace the entire unit with a new or reconditioned unit.
Index Numerics battery checking 93, 142 failure 298 LED 269 reconditioning 94, 143 reported events 277 BBU, reported events 279 blower, reported events 278 boot the subsystem 84, 190 browser, does not connect 301 buzzer settings 94, 193, 203 silence 94 sounding 265, 291 test 95 10GB Truncate 88, 138, 250 2 TB Limitation 248, 304 A about this manual 1 adaptive writeback cache defined 249 enable 88, 138 alarm cancel 94, 193, 203 sounds 265, 291 alias controller 88, 138 disk array 108, 111, 112, 151, 157
VessRAID 1000s Series Product Manual command queuing, physical drives delete, cont.
Index disk array, cont.
VessRAID 1000s Series Product Manual forced unlock 58 FRU VPD information initiator, cont.
Index LCD panel, cont.
VessRAID 1000s Series Product Manual locate controller 138 disk array 156, 210 enclosure 90, 143 logical drive 164, 214 physical drive 96, 97, 100, logical drive, cont.
Index O physical drive, cont.
VessRAID 1000s Series Product Manual RAID, cont introduction 233 mirror 235 mirror + stripe 239 stripe 234 striping of distributed parity read cache physical drive 97, 145 policy 112, 120, 151, 158, 208 policy, defined 249 read check table 123 reassigned block threshold 55, 169 rebuild disk array 114, 154, 292 manual 115 rate 54, 168 reported events 286, 287 recipients, Netsend 76 recondition a battery 94, 143 red X 266, 296 Redundancy Check 57, 121, 164 rate 54, 169 reported events 287 regulatory statem
Index reported events, cont.
VessRAID 1000s Series Product Manual SNMP service 76, 183 settings 74, 182 trap sinks 75, 183 Software Services 71 Spare Check reported events 288 run 127, 160 spare drive create 125, 159, 215 delete 126, 161, 216 description 251 in rebuild 291 locate 124, 216 reported events 288 select physical drive 125, 159 settings 126, 160 Spare Check 127, 160 transition 116 view 124 specifications, VessRAID 6 stale condition 99, 146 statistics clear 81, 186 controller 87, 137 physical drive 98, 146 SAS port 67, 167 s
Index Transition automatic 263 defined 261 manual 263 rate 54, 169 reported events 289 spare drive 116 transport disk array 117, 154 physical drive failure trap sinks 75, 183 VessRAID, cont.
VessRAID 1000s Series Product Manual WebPAM PROe, cont.