User Manual

190
Vess A2000 Series Product Manual
Examples
event
event -v
event -l nvram
event -a clear -lnvram
event -c 200
event -a list -i852 -c200
Options
-a <action> Specifi es the action to perform.
list (Default) Displays information and status of the enclosure.
mod Modifi es settings. Requires the -s option.
locate Locates an enclosure by fl ashing its LEDs.
-e <encl id> Enclosure ID. The default value is 1 if unspecifi ed.
For list action, the default is for all enclosures if unspecifi ed.
-s “<option>=<value>” Specifi es the settings to change. Applies to the JBOD enclosures only.
tempwarning= (25-45) Enclosure warning theshold temperature, in degrees Celsius.
tempcritical= (30-51) Enclosure critical theshold temperature, in degrees Celsius.
ctrltempwarning= (90-95) Controller warning theshold temperature, in degrees Celsius.
ctrltempcritical= (100-105) Controller critical threshold temperature, in degrees Celsius.
-t <FRU type> Specifi es which type of FRU to locate. Requires -a locate option.
ctrl Locates the controller.
cooling Locates the cooling unit.