ULTRATRAK100 TX4 and ULTRATRAK100 TX8 User Manual

UltraTrak100 TX4 and UltraTrak100 TX8
User Manual
20
The first line of the Idle mode menu will display one of the following status
messages:
Array Functional
The array is fully operational, and no problems are
present.
Array Critical
The array is operational, but has lost its fault tolerance.
For RAID array levels 1, 3 and, 5 the array contains a
failed drive. The user should identify and replace the
failed drive.
Array Offline
The array is no longer operational. The array must be
rebuilt from the last tape backup or other device. For
RAID levels 1, 3, and 5, at least two or more drives in
the array have failed. For a RAID 0 array, at least one
drive has failed. The user should identify and replace
the failed drives.
The second line of the Idle mode menu can also provides the following error
information:
Fan Error
Fan speed is <2000RPM or >5500RPM
Array Rebuilding xx%
At least one array is rebuilding
Array Synchronizing xx%
At least one array doing synchronize
C
ONFIGURATION
M
ENU
In Configuration mode you may view the status of the UltraTrak100 system and
configure both UltraTrak100 hardware and arrays. The main configuration menu
allows the user to select the following menus:
View Status
Configure Array
Configure Cache
Configure SCSI
Press
or to move these items on the LCD.
What you can do:
Press
SEL
:
Selects one of the following active functions:
View Status
Moves the display to the
View Status
menu.
Configure Array
Moves the display to the
Configure Array
menu.
Configure Cache
Moves the display to the
Configure Cache
menu.
Configure SCSI
Moves the display to the
Configure SCSI
menu.
Press
:
Moves the active message line up. (
Active is marked by *.
)
Press
:
Moves the active message line down. (
Active is marked by *.
)
Press
EXIT
: Returns to the
Idle
mode.