User manual

SuperTrak SX6000™ User Manual Chapter 3
- 13 -
Size
This is the MB (Megabyte) data size of the indicated array.
Track-Mapping
This is the CHS (Cylinder/Head/Sector) equivalent of the array geometry as
hosted by the SuperTrak SX6000 BIOS int 13h disk services.
Status
Shows one of three possible array status conditions:
Functional
The array is fully operational, and no problems are present.
Critical
The array is operational, but has lost its fault tolerance. For RAID
array levels 1, 0+1, 3 and, 5 the array contains a failed drive. The
user should identify and replace the failed drive.
Offline
The array is no longer operational and the SuperBuild utility cannot
rebuild the array. The array must be rebuilt from the last tape
backup or other device. The user should identify and replace the
failed drives. For RAID levels 1, 3, and 5, at least two or more
drives in the array have failed. For a RAID 0 array, at least one
drive has failed.