Table Of Contents
Chapter 8: Troubleshooting
271
2. Click the Disk Arrays icon.
3. Click the Disk Array icon.
If there are multiple disk arrays, choose the icon with the yellow !.
4. From the dropdown menu on the Background Activities tab, choose Start
Rebuild.
5. Choose Source physical drive.
The Source is a remaining functional physical drive in the disk array.
6. Choose the Target physical drive.
The Target is the replacement physical drive.
7. Click the Submit button.
The Disk Array Background Activity tab shows rebuild progress on the
replacement (target) physical drive. Depending the size of the physical disk
involved, this process will take some time.
To view more information, click the Rebuild on PDx link.
Rebuilding with SuperBuild
To manually rebuild a disk array in the SuperBuild Utility:
1. In the Main Menu, highlight Disk Array Management and press Enter.
The Disk Array Management screen displays.
2. Highlight the Disk Array with the failed drive and press Enter.
The Disk Array Info and Setting screen displays.
3. Highlight Physical Drives in the Array and press Enter.
Note the ID numbers of the physical drives that are still functional.
4. Highlight Start Manual Rebuild and press Enter.
The Manual Rebuild screen displays.
5. Highlight the Source Sequence Number and press Enter.
Then type the ID number of one of the physical drives you noted in step 3
and press Enter.
6. Highlight the Target Physical Drive ID and press Enter.
Then type the ID number of the new drive and press Enter.
7. Highlight Start Manual Rebuild and press Enter.
The time required for the Rebuild depends on the number and size of your
logical drives. You can monitor the progress of the Rebuild under
Background Activity.