User manual

Table Of Contents
Chapter 8: Troubleshooting
267
Critical & Offline Logical Drives
A fault-tolerant logical drive—RAID 1, 1E, 5, 6, 10, 50, or 60—goes critical when
a physical drive is removed or fails. Due to the fault tolerance of the logical drive,
the data is still available and online. However, once the logical drive goes critical,
the logical drive has lost its fault tolerance, and performance may be adversely
affected.
If the fault was caused by a failed physical drive, the failed drive must be
replaced in order for the disk array to rebuild and restore the logical drives on the
array to normal or OK status.
If your fault-tolerant logical drive—RAID 1, 1E, 5, 6, 10, 50, or 60—goes offline,
contact Technical Support. See page 277.
A non-fault tolerant logical drive—RAID 0—goes offline when a physical drive is
removed or fails. Since the logical drive is not fault tolerant, the data stored in the
logical drive is no longer accessible.
If one physical drive fails, all of the data on the RAID 0 logical drive is lost. You
must replace the failed drive. Then, if the logical drive had more than one
physical drive, delete the logical drive and re-create it. Restore the data from a
backup source.
Finding the Failed Drive in SuperBuild
To identify a failed physical drive:
1. In the Main Menu, highlight Physical Drive Management and press Enter.
The Physical Drive Management screen displays.
2. Compare the list of physical drives on the screen against the actual physical
drives attached to the SuperTrak controller.
Warning
Take no further corrective action until you have consulted with
Technical Support. See page 277.